Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 SLOVAMID® 6 NG1 GF 20 HLS PLASTCOM SLOVAKIA
--
--
Filler, glass fiber reinforced material, 20%, filler by weight,
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | PLASTCOM SLOVAKIA/SLOVAMID® 6 NG1 GF 20 HLS |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 214 °C |
| Melting temperature | ISO 3146 | 225 °C | |
| Vicat softening temperature | ISO 306/B | 202 °C |
| mechanical properties | Test Condition | Test Method | PLASTCOM SLOVAKIA/SLOVAMID® 6 NG1 GF 20 HLS |
|---|---|---|---|
| Bending modulus | ISO 178 | 6200 MPa | |
| bending strength | ISO 178 | 192 MPa | |
| Tensile modulus | ISO 527-2 | 7600 MPa | |
| Tensile strain | Yield | ISO 527-2 | 3.0 % |
| tensile strength | Yield | ISO 527-2 | 150 MPa |
| Physical properties | Test Condition | Test Method | PLASTCOM SLOVAKIA/SLOVAMID® 6 NG1 GF 20 HLS |
|---|---|---|---|
| density | ISO 1183 | 1.28 g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 5.0 g/10min |
| Shrinkage rate | TD | STM640808 | 0.53 % |
| MD | STM640808 | 0.30 % | |
| water content | ISO 960 | 0.15 % |
| impact performance | Test Condition | Test Method | PLASTCOM SLOVAKIA/SLOVAMID® 6 NG1 GF 20 HLS |
|---|---|---|---|
| Charpy Notched Impact Strength | -20°C | ISO 179 | 7.0 kJ/m² |
| 23°C | ISO 179 | 8.0 kJ/m² | |
| Impact strength of simply supported beam without notch | -20°C | ISO 179 | 48 kJ/m² |
| 23°C | ISO 179 | 53 kJ/m² |
| flammability | Test Condition | Test Method | PLASTCOM SLOVAKIA/SLOVAMID® 6 NG1 GF 20 HLS |
|---|---|---|---|
| UL flame retardant rating | UL 94 | HB |