Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

TPC-ES UM551-V DSM Additive Manufacturing
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | DSM Additive Manufacturing/UM551-V |
|---|---|---|---|
| Shore hardness | ShoreD,3Sec | ISO 868 | 55 |
| ShoreD,15Sec | ISO 868 | 55 |
| thermal performance | Test Condition | Test Method | DSM Additive Manufacturing/UM551-V |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 85.0 °C |
| Melting temperature | ISO 11357-3 | 200 °C | |
| Vicat softening temperature | ISO 306/B50 | 90.0 °C |
| mechanical properties | Test Condition | Test Method | DSM Additive Manufacturing/UM551-V |
|---|---|---|---|
| Nominal tensile fracture strain | ISO 527-2 | 380 % | |
| Tensile modulus | ISO 527-2 | 250 MPa | |
| tensile strength | Break | ISO 527-2 | 27.0 MPa |
| 100%Strain | ISO 527-2 | 17.5 MPa | |
| 10%Strain | ISO 527-2 | 13.0 MPa |
| Electrical performance | Test Condition | Test Method | DSM Additive Manufacturing/UM551-V |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | |
| Dielectric strength | IEC 60243-1 | 20 kV/mm | |
| Dissipation factor | 100Hz | IEC 60250 | 2E-06 |
| Relative permittivity | 100Hz | IEC 60250 | 5.20 |
| Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm |
| Physical properties | Test Condition | Test Method | DSM Additive Manufacturing/UM551-V |
|---|---|---|---|
| density | ISO 1183 | 1.28 g/cm³ | |
| melt mass-flow rate | 230°C/2.16kg | ISO 1133 | 14 g/10min |
| Melt Volume Flow Rate (MVR) | 230°C/2.16kg | ISO 1133 | 15.0 cm³/10min |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.25 % |
| Saturation,23°C | ISO 62 | 0.60 % |
| impact performance | Test Condition | Test Method | DSM Additive Manufacturing/UM551-V |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | NoBreak |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | NoBreak |
| flammability | Test Condition | Test Method | DSM Additive Manufacturing/UM551-V |
|---|---|---|---|
| Flammability level | 1.5mm | IEC 60695-11-10,-20 | V-2 |