Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
ASA 797SE BASF GERMANY
Luran®S 
Casters、Automotive Applications、Fitness equipment、building materials、Profile、Application in the automo、sporting goods
High mobility
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodBASF GERMANY/797SE
Charpy Notched Impact Strength23°CISO 17940 kJ/m²
-30°CISO 1799.0 kJ/m²
Impact strength of cantilever beam gap23°CISO 180/A30 kJ/m²
-30°CISO 180/A10 kJ/m²
hardnessTest ConditionTest MethodBASF GERMANY/797SE
ball-indentation hardnessISO 2039-165.0 Mpa
filmTest ConditionTest MethodBASF GERMANY/797SE
elongation断裂ISO 527-311 %
Mechanical propertiesTest ConditionTest MethodBASF GERMANY/797SE
Tensile modulusISO 527-22000 Mpa
bending strengthISO 17860.0 Mpa
tensile strength 屈服,23°CISO 527-242.0 Mpa
Tensile strain屈服,23°CISO 527-23.5 %
Tensile creep modulus1000hrISO 899-11100 Mpa
Electrical performanceTest ConditionTest MethodBASF GERMANY/797SE
dielectric constant100HzIEC 602503.80
Volume resistivityIEC 600931E+14 ohms·cm
Dissipation Factor100HzIEC 602509E-03
Surface ResistivityIEC 600931E+13 ohms
Dissipation Factor1MHzIEC 602500.026
physical property Test ConditionTest MethodBASF GERMANY/797SE
Apparent density0.59 g/cm³
Shrinkage rateISO 294-40.50-0.90 %
Water absorption rate平衡,23°C,50%RHISO 620.35 %
饱和,23°CISO 621.7 %
densityISO 11831.07 g/cm³
Melt volume flow rate220°C/10.0kgISO 11335.50 cm3/10min
Thermal performanceTest ConditionTest MethodBASF GERMANY/797SE
thermal conductivityDIN 526120.17 W/m/K
Heat distortion temperature1.8MPa,Annealed,HDTISO 75-2/A95.0 °C
vicat--ISO 306/A50104 °C
--ISO 306/B5090.0 °C
Linear coefficient of thermal expansionMDISO 11359-28.0E-5to1.1E-4 cm/cm/°C
Heat distortion temperature0.45MPa,Annealed,HDTISO 75-2/B100 °C

Contact Us

Get App

Top