Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA66 A216 S30 SOLVAY FRANCE
TECHNYL® 
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodSOLVAY FRANCE/A216 S30
Impact strength of simply supported beam without notch23°CISO 179/1eUNoBreak
Suspended wall beam without notch impact strength23°CISO 180/1UNoBreak
Electrical performanceTest ConditionTest MethodSOLVAY FRANCE/A216 S30
relative permittivityIEC 602502.90
Dissipation FactorIEC 602500.030
Volume resistivityIEC 600931E+15 ohms·cm
Compared to the Leakage Tracking Index (CTI)解决方案BIEC 60112 V
解决方案AIEC 60112 V
dielectric strength2.00mmIEC 60243-125 KV/mm
Surface ResistivityIEC 600931E+15 ohms
Mechanical propertiesTest ConditionTest MethodSOLVAY FRANCE/A216 S30
Tensile modulus23°CISO 527-2/1A3200 Mpa
Tensile strain断裂,23°CISO 527-2>30 %
bending strength23°CISO 178120 Mpa
Tensile strain屈服,23°CISO 527-24.5 %
Flexural modulus23°CISO 1782800 Mpa
bending strength23°CASTM D790125 Mpa
tensile strength 断裂,23°CISO 527-2/1A55.0 Mpa
屈服,23°CASTM D63885.0 Mpa
屈服,23°CISO 527-2/1A85.0 Mpa
Flexural modulus23°CASTM D7903000 Mpa
elongation断裂,23°CASTM D63830 %
flammabilityTest ConditionTest MethodSOLVAY FRANCE/A216 S30
Burning wire flammability index0.8mmIEC 60695-2-12650 °C
UL flame retardant rating3.2mmUL 94V-2
GWIT1.6mmIEC 60695-2-13650 °C
Limiting Oxygen IndexISO 4589-226 %
UL flame retardant rating1.6mmUL 94V-2
physical property Test ConditionTest MethodSOLVAY FRANCE/A216 S30
Water absorption rate23°C,24hrISO 621.3 %
平衡,23°C,50%RHISO 622.9 %
Thermal performanceTest ConditionTest MethodSOLVAY FRANCE/A216 S30
Heat distortion temperature1.8MPa,未退火,HDTISO 75-2/Af75.0 °C
melting temperatureISO 11357-3263 °C
Heat distortion temperature0.45MPa,未退火,HDTASTM D648220 °C
0.45MPa,未退火,HDTISO 75-2/Bf200 °C