Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC HP-1000XA K24970 LOTTE KOREA
INFINO®
Automotive Applications,Application in the automotive field
High mobility
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | LOTTE KOREA/HP-1000XA K24970 |
|---|---|---|---|
| Rockwell hardness | R-Scale | ASTM D785 | 113 |
| R-Scale | ISO 2039-2 | 113 |
| thermal performance | Test Condition | Test Method | LOTTE KOREA/HP-1000XA K24970 |
|---|---|---|---|
| Hot deformation temperature | 0.45MPa,Annealed,4.00mm | ISO 75-2/B | 125 °C |
| 1.8MPa,Unannealed,4.00mm | ISO 75-2/A | 102 °C | |
| 1.8MPa,Annealed,4.00mm | ISO 75-2/A | 112 °C | |
| 1.8MPa,Unannealed,6.40mm | ASTM D648 | 110 °C | |
| 0.45MPa,Unannealed,4.00mm | ISO 75-2/B | 123 °C | |
| Vicat softening temperature | -- | ISO 306/B120 | 125 °C |
| -- | ISO 306/B50 | 123 °C |
| mechanical properties | Test Condition | Test Method | LOTTE KOREA/HP-1000XA K24970 |
|---|---|---|---|
| Bending modulus | ISO 178 | 2100 Mpa | |
| ASTM D790 | 2000 Mpa | ||
| bending strength | ASTM D790 | 74.0 Mpa | |
| ISO 178 | 80.0 Mpa | ||
| elongation | Break | ASTM D638 | 100 % |
| Tensile modulus | ASTM D638 | 2000 Mpa | |
| ISO 527-2/50 | 2000 Mpa | ||
| Tensile strain | Break | ISO 527-2/50 | 100 % |
| tensile strength | Yield | ASTM D638 | 54.0 Mpa |
| Yield | ISO 527-2/50 | 50.0 Mpa | |
| Break | ASTM D638 | 59.0 Mpa | |
| Break | ISO 527-2/50 | 53.0 Mpa |
| Physical properties | Test Condition | Test Method | LOTTE KOREA/HP-1000XA K24970 |
|---|---|---|---|
| melt mass-flow rate | 250°C/10.0kg | ASTM D1238 | 27 g/10min |
| 250°C/10.0kg | ISO 1133 | 27 g/10min | |
| Shrinkage rate | MD:3.20mm | ISO 2577 | 0.40-0.70 % |
| TD:3.20mm | ASTM D955 | 0.40-0.70 % | |
| TD:3.20mm | ISO 2577 | 0.40-0.70 % | |
| MD:3.20mm | ASTM D955 | 0.40-0.70 % |
| impact performance | Test Condition | Test Method | LOTTE KOREA/HP-1000XA K24970 |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 49 kJ/m² |
| Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 45 kJ/m² |