PBT HR5315HFS BK591 DUPONT USA
Cristin®  
Electronic and electrical components,Automotive Applications
Flame retardant,Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | DUPONT USA/HR5315HFS BK591 | 
|---|---|---|---|
| 0.45MPa, unannealed | ISO 75-2/B | 220 °C | |
| 1.8MPa, unannealed | ISO 75-2/A | 200 °C | |
| Glass transition temperature | ISO 11357-2 | 65.0 °C | |
| Melting temperature | ISO 11357-3 | 225 °C | 
| mechanical properties | Test Condition | Test Method | DUPONT USA/HR5315HFS BK591 | 
|---|---|---|---|
| bending strength | ISO 178 | 143 Mpa | |
| Tensile modulus | ISO 527-2 | 5000 Mpa | |
| Tensile strain | Break | ISO 527-2 | 3.3 % | 
| tensile strength | Break | ISO 527-2 | 95.0 Mpa | 
| Electrical performance | Test Condition | Test Method | DUPONT USA/HR5315HFS BK591 | 
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | V | |
| Dielectric strength | IEC 60243-1 | 35 KV/mm | |
| Dissipation factor | 1MHz | IEC 60250 | 0.010 | 
| 100Hz | IEC 60250 | 0.010 | |
| Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
| Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | 
| Physical properties | Test Condition | Test Method | DUPONT USA/HR5315HFS BK591 | 
|---|---|---|---|
| Melt Volume Flow Rate (MVR) | 250°C/2.16kg | ISO 1133 | 13.5 cm3/10min | 
| Shrinkage rate | MD | ISO 294-4 | 0.50 % | 
| TD | ISO 294-4 | 1.1 % | |
| Water absorption rate | 23°C,24hr,2.00mm | ISO 62 | 0.40 % | 
| Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.15 % | 
| impact performance | Test Condition | Test Method | DUPONT USA/HR5315HFS BK591 | 
|---|---|---|---|
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 57 kJ/m² | 
| flammability | Test Condition | Test Method | DUPONT USA/HR5315HFS BK591 | 
|---|---|---|---|
| Burning rate | 1.00mm | ISO 3795 | 32 mm/min | 
| Extreme Oxygen Index | ISO 4589-2 | 20 % | |
| Flammability level | 1.50mm | IEC 60695-11-10,-20 | HB | 
| Filling analysis | Test Condition | Test Method | DUPONT USA/HR5315HFS BK591 | 
|---|---|---|---|
| Melt viscosity | 250°C,1000sec^-1 | ISO 11443 | 175 Pa·s |