Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 ADDINYL A2 V30 ADDIPLAST FRANCE
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Electrical performance | Test Condition | Test Method | ADDIPLAST FRANCE/ADDINYL A2 V30 |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
Volume resistivity | IEC 60093 | 1E+15 ohm-cm | |
dielectric strength | 解决方案 A | IEC 60243-1 | 35 kv/mm |
Mechanical properties | Test Condition | Test Method | ADDIPLAST FRANCE/ADDINYL A2 V30 |
---|---|---|---|
Charpy Notched Impact Strength | ISO 179/1eU | 55 KJ/m2 | |
Impact strength of cantilever beam gap | ISO 180/1A | 11.0 KJ/m2 | |
Tensile stress (fracture) | ISO 527-2 | 180 MPa | |
Charpy Notched Impact Strength | ISO 179/1eA | 10 KJ/m2 | |
Flexural modulus | ISO 178 | 8200 MPa | |
Tensile strain (fracture) | ISO 527-2 | 3.0 % |
physical property | Test Condition | Test Method | ADDIPLAST FRANCE/ADDINYL A2 V30 |
---|---|---|---|
Shore hardness | ISO 868 | 85 | |
density | ISO 1183/A | 1.37 g/cm3 |
Thermal performance | Test Condition | Test Method | ADDIPLAST FRANCE/ADDINYL A2 V30 |
---|---|---|---|
Linear coefficient of thermal expansion | ASTM E831 | 0.000030 cm/cm/℃ | |
melting temperature | DSC法 | ISO 3416 | 260 ℃ |
Heat distortion temperature | 1.8 MPa,未退火,HDT | ISO 75-2/Af | 255 ℃ |
Contact Us
Get App