Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 BG-50S BK EMS-CHEMIE SWITZERLAND
Grilon®
Home appliance components,Automotive interior parts,Electrical applications,Automotive interior parts,Application in the automotive field,Home appliance components,Electrical/Electronic Applications
Glass fiber reinforced,High impact resistance,Filler: Glass fiber reinf,50% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BG-50S BK |
|---|---|---|---|
| Ball Pressure Test | MPa | 270 155 |
| thermal performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BG-50S BK |
|---|---|---|---|
| Continuous use temperature | --4 | °C | 160 -- |
| --3 | °C | 90.0to140 -- | |
| Hot deformation temperature | 8.0MPa,Unannealed | °C | 170 -- |
| 1.8MPa,Unannealed | °C | 210 -- | |
| Linear coefficient of thermal expansion | TD | cm/cm/°C | 1E-04 -- |
| MD | cm/cm/°C | 1.5E-05 -- | |
| Melting temperature | °C | 222 -- |
| mechanical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BG-50S BK |
|---|---|---|---|
| Tensile modulus | MPa | 17500 11500 | |
| Tensile strain | Break | % | 3.0 6.0 |
| tensile strength | Break | 245 MPa |
| Electrical performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BG-50S BK |
|---|---|---|---|
| Compared to the anti leakage trace index | V | -- | |
| Dielectric strength | kV/mm | 40 37 | |
| Surface resistivity | ohms | -- 1E+12 | |
| Volume resistivity | ohms·cm | 1E+14 |
| Physical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BG-50S BK |
|---|---|---|---|
| Shrinkage rate | TD | % | 0.50 -- |
| MD | % | 0.10 -- | |
| Water absorption rate | Saturation,23°C | % | 5.0 -- |
| Equilibrium,23°C,50%RH | % | 1.5 -- |
| impact performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BG-50S BK |
|---|---|---|---|
| Impact strength of simply supported beam without notch | -30°C | kJ/m² | 85 |
| 23°C | kJ/m² | 90 |
| flammability | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/BG-50S BK |
|---|---|---|---|
| Flammability level | 0.8mm | HB -- |