Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

MVLDPE 1018CA EXXONMOBIL USA
Exceed™
Shipping container,chip,film
High impact resistance,high strength
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| Other performance | Test Condition | Test Method | EXXONMOBIL USA/1018CA |
|---|---|---|---|
| Anti adhesive agent | 否 | ||
| PPA | 有 | ||
| Slippery agent | 否 | ||
| thermal stability | 有 |
| Basic Performance | Test Condition | Test Method | EXXONMOBIL USA/1018CA |
|---|---|---|---|
| density | ExxonMobil Method | 0.918 g/cm³ | |
| melt mass-flow rate | ASTM D-1238 | 1 g/10min |
| film | Test Condition | Test Method | EXXONMOBIL USA/1018CA |
|---|---|---|---|
| Dart impact | ASTM D1709A | 460 g | |
| Elmendorf tear strength | MD | ASTM D1922 | 250 g |
| TD | ASTM D1922 | 470 g | |
| elongation | Break | ASTM D882 | 500 % |
| Secant modulus -1% Decant, MD | ASTM D882 | 185 Mpa | |
| Secant modulus -1% Decant, TD | ASTM D882 | 192 Mpa | |
| Tensile strain | Break | ASTM D882 | 600 % |
| tensile strength | Break,TD | ASTM D882 | 42.7 Mpa |
| Break | ASTM D882 | 54.3 Mpa | |
| Yield | ASTM D882 | 9.40 Mpa |
| thermal performance | Test Condition | Test Method | EXXONMOBIL USA/1018CA |
|---|---|---|---|
| Melt Temperature | ExxonMobil Method | 119 °C |
| mechanical properties | Test Condition | Test Method | EXXONMOBIL USA/1018CA |
|---|---|---|---|
| Dart impact | F50 | ASTM D-1709A | 560 g |
| Elmendorf tear strength | MD | ASTM D-1922 | 280 g |
| TD | ASTM D-1922 | 460 g | |
| Elongation at Break | @厚 150μ(5.9mil),MD | ASTM D-882 | 500 % |
| @厚 150μ(5.9mil),TD | ASTM D-882 | 700 % | |
| Puncture resistance | ExxonMobil Method | 4.3 J | |
| Secant modulus | @厚 150μ(5.9mil),1%Strain, TD | ASTM D-882 | 205 Mpa |
| @厚 150μ(5.9mil),1%Strain, MD | ASTM D-882 | 183 Mpa | |
| tensile strength | @厚 150μ(5.9mil),TD | ASTM D-882 | 62.7 Mpa |
| @厚 150μ(5.9mil),MD | ASTM D-882 | 9 Mpa | |
| @厚 150μ(5.9mil),TD,Yield | ASTM D-882 | 9.7 Mpa |
| Physical properties | Test Condition | Test Method | EXXONMOBIL USA/1018CA |
|---|---|---|---|
| melt mass-flow rate | 190°C/2.16kg | ASTM D1238 | 1.0 g/10min |
| optical performance | Test Condition | Test Method | EXXONMOBIL USA/1018CA |
|---|---|---|---|
| gloss | 45° | ASTM D2457 | 39 |
| Across Flow,45° | ASTM D-2457 | 42 | |
| turbidity | ASTM D1003 | 18 % | |
| ASTM D-1003 | 18 % |