Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA6 Nylux 6/G33FL BLK KMI Group, Inc.
--
--
Filler, glass fiber reinforced material, 33%, filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | KMI Group, Inc./Nylux 6/G33FL BLK |
---|---|---|---|
Rockwell hardness | ISO 2039-2 | 122 R |
Mechanical properties | Test Condition | Test Method | KMI Group, Inc./Nylux 6/G33FL BLK |
---|---|---|---|
Flexural modulus | 23°C | ISO 178 | 5800 MPa |
Tensile modulus | 23°C | ISO 527-2 | 8500 MPa |
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 5 kJ/m² |
tensile strength | 23°C | ISO 527-2 | 140 MPa |
elongation at break | 23°C | ISO 527-2 | 3 % |
Electrical performance | Test Condition | Test Method | KMI Group, Inc./Nylux 6/G33FL BLK |
---|---|---|---|
Surface Resistivity | IEC 60093 | 1E+13 Ω.cm | |
Volume resistivity | IEC 60093 | 1E+15 Ω.cm |
Flame retardant performance | Test Condition | Test Method | KMI Group, Inc./Nylux 6/G33FL BLK |
---|---|---|---|
UL flame retardant rating | UL -94 | HB 0.8mm |
physical property | Test Condition | Test Method | KMI Group, Inc./Nylux 6/G33FL BLK |
---|---|---|---|
Water absorption rate | (23°C,24hr) | ISO 62 | 6.0 % |
density | ISO 1183 | 1.36 g/cm³ | |
Water absorption rate | 收缩率 | ISO 2577 | 0.25-0.55 % |
Thermal performance | Test Condition | Test Method | KMI Group, Inc./Nylux 6/G33FL BLK |
---|---|---|---|
vicat | ISO 306/A50 | 210 °C | |
Heat distortion temperature | 1.80MPa退火,HDT | ISO 75-2/Af | 205 °C |
Linear coefficient of thermal expansion | 熔融温度 | ISO 3146 | 220 °C |
Heat distortion temperature | 0.45MPa未退火,HDT | ISO 75-2/Bf | 215 °C |
Contact Us
Get App
Top