PP Fibrolon® P 8540 FKuR Kunststoff GmbH
--
--
Filler, wood fiber, 40%, filler by weight,
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | FKuR Kunststoff GmbH/Fibrolon® P 8540 |
|---|---|---|---|
| Melting temperature | ISO 3146 | 160to180 °C | |
| Vicat softening temperature | ISO 306/A | 155 °C |
| mechanical properties | Test Condition | Test Method | FKuR Kunststoff GmbH/Fibrolon® P 8540 |
|---|---|---|---|
| Bending modulus | ISO 178 | 3500 MPa | |
| bending strength | 3.5%Strain | ISO 178 | 41.0 MPa |
| Fracture bending strain | ISO 178 | 6.0 % | |
| Tensile modulus | ISO 527-2 | 3400 MPa | |
| Tensile strain | Break | ISO 527-2 | 4.5 % |
| Tensile strain change rate | ISO 527 | 3.0 % | |
| tensile strength | Yield | ISO 527-2 | 26.0 MPa |
| Break | ISO 527-2 | 24.0 MPa |
| Physical properties | Test Condition | Test Method | FKuR Kunststoff GmbH/Fibrolon® P 8540 |
|---|---|---|---|
| Apparent density | ISO 60 | 0.36 g/cm³ | |
| density | ISO 1183 | 1.05 g/cm³ | |
| melt mass-flow rate | 190°C/5.0kg | ISO 1133 | 2.0to3.0 g/10min |
| Melt Volume Flow Rate (MVR) | 190°C/5.0kg | ISO 1133 | 3.00to4.00 cm³/10min |
| impact performance | Test Condition | Test Method | FKuR Kunststoff GmbH/Fibrolon® P 8540 |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 3.6 kJ/m² |
| Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 11 kJ/m² |