Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Thermoset KYOCERA TCG1180K2 KYOCERA Chemical Corporation
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Electrical performance | Test Condition | Test Method | KYOCERA Chemical Corporation/KYOCERA TCG1180K2 |
---|---|---|---|
Volume resistivity | 25°C | 4.7E+15 ohms·cm | |
dielectric strength | 25°C | >30 kV/mm |
Mechanical properties | Test Condition | Test Method | KYOCERA Chemical Corporation/KYOCERA TCG1180K2 |
---|---|---|---|
Flexural modulus | 25°C | 8500 MPa | |
bending strength | 25°C | 113 MPa |
flammability | Test Condition | Test Method | KYOCERA Chemical Corporation/KYOCERA TCG1180K2 |
---|---|---|---|
UL flame retardant rating | 1.6mm | UL 94 | V-0 |
physical property | Test Condition | Test Method | KYOCERA Chemical Corporation/KYOCERA TCG1180K2 |
---|---|---|---|
density | 1.72 g/cm³ | ||
Solution viscosity | 3700 mPa·s |
Thermal performance | Test Condition | Test Method | KYOCERA Chemical Corporation/KYOCERA TCG1180K2 |
---|---|---|---|
Glass Transition Temperature | TMA | 110 °C | |
Linear coefficient of thermal expansion | MD | TMA | 4.3E-05 cm/cm/°C |