Material Comparison
Add Comparison Model
Select Products for Comparison (1/4)
Highlight Differences
Hide Same
Product Name / Manufacturer / Model
Grade
Certificates
Reference Price
| mechanical properties | Test Condition | Test Method | ASAHI JAPAN/FG171 |
|---|---|---|---|
| elongation | Break | ASTM D638 | 2.5 % |
| tensile strength | Break,23°C | ISO 527-2 | 154 Mpa |
| bending strength | 23°C | ISO 178 | 244 Mpa |
| tensile strength | ASTM D638 | 162 Mpa | |
| bending strength | ASTM D790 | 256 Mpa | |
| Bending modulus | 23°C | ISO 178 | 9700 Mpa |
| ASTM D790 | 8900 Mpa | ||
| Tensile modulus | 23°C | ISO 527-2 | 10200 Mpa |
| Tensile strain | Break,23°C | ISO 527-2 | 2.5 % |
| flammability | Test Condition | Test Method | ASAHI JAPAN/FG171 |
| UL flame retardant rating | 0.75mm | UL 94 | V-0 |
| Burning wire flammability index | 3.0mm | IEC 60695-2-12 | 960 °C |
| Electrical performance | Test Condition | Test Method | ASAHI JAPAN/FG171 |
| Volume resistivity | 23°C | IEC 60093 | 1E+15 ohms·cm |
| Surface resistivity | ASTM D257 | 1E+14 ohms | |
| Compared to the anti leakage trace index | 3.00mm | IEC 60112 | PLC 2 |
| Volume resistivity | ASTM D257 | 1E+15 ohms·cm | |
| Surface resistivity | IEC 60093 | 1E+14 ohms | |
| Dielectric strength | IEC 60243-1 | 28 KV/mm | |
| ASTM D149 | 28 KV/mm | ||
| Physical properties | Test Condition | Test Method | ASAHI JAPAN/FG171 |
| Shrinkage rate | 吸水率(Saturation,23°C) | Internal Method | -- % |
| MD | Internal Method | 0.40 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | -- % |
| Shrinkage rate | TD | Internal Method | 0.90 % |
| thermal performance | Test Condition | Test Method | ASAHI JAPAN/FG171 |
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D648 | 255 °C |
| Linear coefficient of thermal expansion | MD | ASTM D696 | 3E-05 cm/cm/°C |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 256 °C |
| 1.8MPa,Unannealed | ASTM D648 | 250 °C | |
| 1.8MPa,Unannealed | ISO 75-2/A | 240 °C | |
| impact performance | Test Condition | Test Method | ASAHI JAPAN/FG171 |
| Impact strength of simply supported beam without notch | ISO 179 | 67 kJ/m² | |
| hardness | Test Condition | Test Method | ASAHI JAPAN/FG171 |
| Rockwell hardness | M-Scale | ASTM D785 | 95 |
| M-Scale | ISO 2039-2 | 95 |