Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA46 F12 DSM HOLAND
Stanyl®
Home appliance components、Electronic and electrical
Glass fiber reinforced、Thermal stability
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | DSM HOLAND/F12 |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 65 kJ/m² |
Mechanical properties | Test Condition | Test Method | DSM HOLAND/F12 |
---|---|---|---|
Tensile modulus | ISO 527-2 | 13500 Mpa | |
bending strength | ISO 178 | 280 Mpa | |
Tensile strain | 断裂 | ISO 527-2 | 1.9 % |
Flexural modulus | ISO 178 | 14500 Mpa | |
tensile strength | 断裂 | ISO 527-2 | 170 Mpa |
Electrical performance | Test Condition | Test Method | DSM HOLAND/F12 |
---|---|---|---|
relative permittivity | 100 Hz | IEC 60250 | 4.20 |
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
dielectric strength | IEC 60243-1 | 33 KV/mm | |
Volume resistivity | IEC 60093 | > 1.0E+15 ohms·cm | |
relative permittivity | 1 MHz | IEC 60250 | 3.90 |
flammability | Test Condition | Test Method | DSM HOLAND/F12 |
---|---|---|---|
Flammability level | UL 94 | V-0 |
physical property | Test Condition | Test Method | DSM HOLAND/F12 |
---|---|---|---|
Water absorption rate | 平衡, 23°C, 50% RH | ISO 62 | 1.5 % |
Shrinkage rate | 流量 | ISO 294-4 | 0.30 % |
横向流量 | ISO 294-4 | 0.85 % |
Thermal performance | Test Condition | Test Method | DSM HOLAND/F12 |
---|---|---|---|
melting temperature | ISO 11357-3 | 325 °C | |
Heat distortion temperature | 1.8 MPa, 未退火,HDT | ISO 75-2/A | 305 °C |
RTI Elec | 0.35 mm | UL 746 | 140 °C |
Linear coefficient of thermal expansion | 流动 | ASTM D696 | 3.0E-5 cm/cm/°C |
横向 | ASTM D696 | 3.5E-5 cm/cm/°C |
Contact Us