Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEI 2100-1000 SABIC INNOVATIVE US
ULTEM™
Fiber grade,plug,Laptop case,Fatigue relief supplies,Washer
Glass fiber reinforced,wear resistant,High rigidity,Thermal stability,Flame retardant,High impact resistance,Filler: Glass fiber reinf,10% filler by weight,10% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
hardness | Test Condition | Test Method | SABIC INNOVATIVE US/2100-1000 |
---|---|---|---|
Rockwell hardness | M-Scale | ASTM D785 | 114 |
thermal performance | Test Condition | Test Method | SABIC INNOVATIVE US/2100-1000 |
---|---|---|---|
Hot deformation temperature | 1.8MPa,Unannealed,6.40mm | ASTM D648 | 209 °C |
0.45MPa,Unannealed,6.40mm | ASTM D648 | 210 °C | |
Linear coefficient of thermal expansion | MD:-20to150°C | ASTME831 | 3.2E-05 cm/cm/°C |
RTI Elec | UL 746 | 170 °C | |
RTI Imp | UL 746 | 170 °C | |
RTI Str | UL 746 | 170 °C | |
Vicat softening temperature | ASTM D15255 | 223 °C |
mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE US/2100-1000 |
---|---|---|---|
Bending modulus | 100mmSpan | ASTM D790 | 5170 Mpa |
bending strength | Break,100mmSpan | ASTM D790 | 200 Mpa |
elongation | Break | ASTM D638 | 6.0 % |
Tensile modulus | ASTM D638 | 4690 Mpa | |
tensile strength | Yield | ASTM D638 | 114 Mpa |
Break | ASTM D638 | 116 Mpa |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE US/2100-1000 |
---|---|---|---|
Arc resistance | ASTM D495 | PLC6 | |
Compared to the anti leakage trace index | CTI | UL 746 | PLC 4 |
Dielectric constant | 1kHz | ASTM D150 | 3.50 |
Dielectric strength | 1.60mm,inOil | ASTM D149 | 28 KV/mm |
Dissipation factor | 1kHz | ASTM D150 | 1.4E-03 |
2.45GHz | ASTM D150 | 4.6E-03 | |
High arc combustion index | HAI | UL 746 | PLC 4 |
High voltage arc tracing rate | HVTR | UL 746 | PLC 2 |
Hot wire ignition | HWI | UL 746 | PLC 1 |
Volume resistivity | ASTM D257 | 1E+17 ohms·cm |
Physical properties | Test Condition | Test Method | SABIC INNOVATIVE US/2100-1000 |
---|---|---|---|
density | ASTM D792 | 1.34 g/cm³ | |
melt mass-flow rate | 337°C/6.6kg | ASTM D1238 | 7.0 g/10min |
Shrinkage rate | MD:3.20mm | Internal Method | 0.50-0.60 % |
Water absorption rate | 24hr | ASTM D570 | 0.21 % |
Equilibrium,23°C | ASTM D570 | 1.2 % |
impact performance | Test Condition | Test Method | SABIC INNOVATIVE US/2100-1000 |
---|---|---|---|
Impact strength of cantilever beam gap | 3.20mm | ASTM D256 | 460 J/m |
23°C | ASTM D256 | 53 J/m | |
23°C | ASTM D4812 | 480 J/m |
flammability | Test Condition | Test Method | SABIC INNOVATIVE US/2100-1000 |
---|---|---|---|
Extreme Oxygen Index | ASTM D2863 | 47 % | |
NBSSmokeDensity-Flaming,Ds,4min | ASTME662 | 1.80 | |
UL flame retardant rating | 1.9mm | UL 94 | 5VA |
0.41mm | UL 94 | V-0 |