Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 FR52G20LX DUPONT USA
Zytel®
Automotive components,Home appliance components
Flame retardant,Thermal stability,Filler: Glass fiber reinf,20% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | DUPONT USA/FR52G20LX |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | kJ/m² | 40 |
23°C | kJ/m² | 40 |
thermal performance | Test Condition | Test Method | DUPONT USA/FR52G20LX |
---|---|---|---|
Linear coefficient of thermal expansion | TD | cm/cm/°C | 6.8E-05 -- |
TD:55到160°C | cm/cm/°C | 1E-04 -- | |
MD:-40到23°C | cm/cm/°C | 2.7E-05 -- | |
Heat Deflection Temperature | 1.8MPa,未退火,HDT | °C | 276 -- |
melting temperature | °C | 310 -- | |
Linear coefficient of thermal expansion | MD | cm/cm/°C | 2.5E-05 -- |
MD:55到160°C | cm/cm/°C | 2.1E-05 -- | |
TD:-40到23°C | cm/cm/°C | 6.4E-05 -- |
mechanical properties | Test Condition | Test Method | DUPONT USA/FR52G20LX |
---|---|---|---|
bending strength | MPa | 215 180 | |
tensile strength | 断裂 | 135 MPa | |
flexural modulus | MPa | 7800 8200 | |
Tensile strain | 断裂 | % | 2.4 2.2 |
Tensile modulus | 8200 MPa |
Electrical performance | Test Condition | Test Method | DUPONT USA/FR52G20LX |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | V | -- | |
volume resistivity | ohms·cm | >1.0E+15 -- | |
dielectric strength | kV/mm | 42 -- |
Physical properties | Test Condition | Test Method | DUPONT USA/FR52G20LX |
---|---|---|---|
shrinkage rate | TD | % | 1.1 -- |
MD | % | 0.30 -- |
flammability | Test Condition | Test Method | DUPONT USA/FR52G20LX |
---|---|---|---|
Flammability level | 0.750mm | V-0 -- | |
Limiting Oxygen Index | % | 35 -- | |
Flammability level | 1.50mm | V-0 -- | |
Burning wire flammability index | 0.400mm | °C | 960 -- |
Hot filament ignition temperature | 0.400mm | °C | 725 -- |
Contact Us
Get App
Top