plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PBT HR5315 DUPONT USA
Cristin® 
Electronic and electrical components
Hydrolysis resistance,Glass fiber reinforced,Filler: Glass fiber reinf,15% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodDUPONT USA/HR5315
Rockwell hardnessR-ScaleISO 2039-2115
thermal performanceTest ConditionTest MethodDUPONT USA/HR5315
Glass transition temperatureISO 11357-265.0 °C
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B220 °C
1.8MPa,UnannealedISO 75-2/A200 °C
Linear coefficient of thermal expansionTDISO 11359-21.1E-04 cm/cm/°C
MDISO 11359-24.1E-05 cm/cm/°C
Melting temperatureISO 11357-3225 °C
ISO 3146225
mechanical propertiesTest ConditionTest MethodDUPONT USA/HR5315
Bending modulusISO 1784700 Mpa
23℃ISO 1784500 MPa
bending strengthISO 178150 Mpa
23℃ISO 178140 MPa
Suspended wall beam without notch impact strength23 ℃, Type 1ISO 18045 kJ/m²
Tensile creep modulus1hrISO 899-15000 Mpa
1000hrISO 899-14200 Mpa
Tensile modulusISO 527-25200 Mpa
23℃ISO 527-15200 MPa
Tensile strain23℃,BreakISO 527-13 %
BreakISO 527-23.0 %
tensile strengthBreakISO 527-295.0 Mpa
Electrical performanceTest ConditionTest MethodDUPONT USA/HR5315
Compared to the anti leakage trace indexIEC 60112PLC 2
Dielectric strengthIEC 60243-142 KV/mm
Dissipation factor1MHzIEC 602500.010
100HzIEC 602500.010
Relative permittivity100HzIEC 602503.80
1MHzIEC 602503.60
Surface resistivityIEC 600931E+13 ohms
Volume resistivityIEC 60093>1.0E+15 ohms·cm
Physical propertiesTest ConditionTest MethodDUPONT USA/HR5315
FlowLength22.00mm,FlowLength430 mm
MediumDensity1.14 g/cm³
Shrinkage rateMDISO 294-40.50 %
FlowISO 294-40.5 %
TDISO 294-41.1 %
Across FlowISO 294-41.1 %
SpecificHeatCapacity of Melt1860 J/kg/°C
StickinessISO 30795.0 cm³/g
ThermalConductivityofMelt0.26 W/m/K
Top out temperature170 °C
Water absorption rateEquilibrium,23°C,2.00mm,50%RHISO 620.15 %
Saturation,23°C,2.00mmISO 620.40 %
impact performanceTest ConditionTest MethodDUPONT USA/HR5315
Impact strength of simply supported beam without notch-30°CISO 179/1eU30 kJ/m²
23°CISO 179/1eU60 kJ/m²
Suspended wall beam without notch impact strength23°CISO 180/1U45 kJ/m²
-30°CISO 180/1U40 kJ/m²
-40°CISO 180/1U30 kJ/m²
flammabilityTest ConditionTest MethodDUPONT USA/HR5315
Burning rate1.00mmISO 3795<100 mm/min
Extreme Oxygen IndexISO 4589-220 %
Flammability level1.5mmIEC 60695-11-10,-20HB
FMVSS flammabilityFMVSS302B