plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA12 6333 SA01 MED ARKEMA FRANCE
--
Medical and nursing supplies
Low wear
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodARKEMA FRANCE/6333 SA01 MED
Shore hardnessShore D, 15 SecISO 7619-158
thermal performanceTest ConditionTest MethodARKEMA FRANCE/6333 SA01 MED
Melting temperatureISO 11357-3169 °C
Vicat softening temperatureISO 306/B50157 °C
mechanical propertiesTest ConditionTest MethodARKEMA FRANCE/6333 SA01 MED
Nominal tensile fracture strainISO 527-2> 50 %
Tensile modulusISO 527-2307 Mpa
Tensile strainYieldISO 527-222 %
tensile strengthYieldISO 527-219.0 Mpa
Physical propertiesTest ConditionTest MethodARKEMA FRANCE/6333 SA01 MED
Shrinkage rate横向FlowISO 294-41.4 %
FlowISO 294-41.2 %
Water absorption rateSaturation, 23°CISO 621.1 %
Equilibrium, 23°C, 50% RHISO 620.70 %
impact performanceTest ConditionTest MethodARKEMA FRANCE/6333 SA01 MED
Impact strength of simply supported beam without notch-30°CISO 179/1eU--
23°CISO 179/1eU--
squeeze outTest ConditionTest MethodARKEMA FRANCE/6333 SA01 MED
drying temperature65 to 75 °C
drying time4.0 to 6.0 hr
Melt Temperature210 to 240 °C
injectionTest ConditionTest MethodARKEMA FRANCE/6333 SA01 MED
drying temperature65 to 75 °C
drying time4.0 to 6.0 hr
Mold temperature25 to 60 °C
Processing (melt) temperature230 to 290 °C