Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC 7022E TW3 MITSUBISHI ENGINEERING JAPAN
IUPILON™
Medical packaging
Low viscosity,transparent
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/7022E TW3 |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | NoBreak |
Electrical performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/7022E TW3 |
---|---|---|---|
dielectric strength | IEC 60243-1 | 18 KV/mm | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm | |
Dissipation Factor | 100Hz | IEC 60250 | 1.7E-03 |
relative permittivity | 100Hz | IEC 60250 | 3.20 |
1MHz | IEC 60250 | 3.20 | |
Surface Resistivity | IEC 60093 | 3E+14 ohms | |
Dissipation Factor | 1MHz | IEC 60250 | 9.7E-03 |
Mechanical properties | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/7022E TW3 |
---|---|---|---|
Tensile modulus | ISO 527-2 | 2700 Mpa | |
Nominal tensile fracture strain | ISO 527-2 | >50 % | |
bending strength | ISO 178 | 101 Mpa | |
Flexural modulus | ISO 178 | 2500 Mpa | |
Tensile strain | 屈服 | ISO 527-2 | 6.3 % |
tensile strength | 屈服 | ISO 527-2 | 64.0 Mpa |
physical property | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/7022E TW3 |
---|---|---|---|
Shrinkage rate | TD | ISO 294-4 | 0.60 % |
MD | ISO 294-4 | 0.60 % | |
Melt volume flow rate | 300°C/1.2kg | ISO 1133 | 23.0 cm3/10min |
Thermal performance | Test Condition | Test Method | MITSUBISHI ENGINEERING JAPAN/7022E TW3 |
---|---|---|---|
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/A | 114 °C |
Linear coefficient of thermal expansion | MD | ISO 11359-2 | 6.5E-05 cm/cm/°C |
TD | ISO 11359-2 | 6.6E-05 cm/cm/°C |