Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
TPV 101-73 CELANESE USA
Santoprene™
Fitness equipment、Automotive Applications、Electrical applications、Application in the automo、packing、Pipe fittings、Home appliance components、Consumer product applicat、Parts under the hood of a、Outdoor applications、Washer、Electrical components、diaphragm
High temperature resistan、Aging resistance、Flame retardant
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodCELANESE USA/101-73
Shore Hardness邵氏A,15秒,23°CISO86878
Electrical performanceTest ConditionTest MethodCELANESE USA/101-73
High voltage arc ignition resistance indexPLCUL746PLC6
High arc combustion index (HAI)HAIUL746PLC 0
DielectricConstant23°C,1.98mmIEC602502.50
Hot wire ignition (HWI)1.5mmUL746PLC 3
dielectric strength23°C,2.00mmASTMD14927 KV/mm
DielectricConstant23°C,1.98mmASTMD1502.50
High Voltage Arc Traceability Rate (HVTR)HVTRUL746PLC 1
Hot wire ignition (HWI)3.0mmUL746PLC 3
Compared to the Leakage Tracking Index (CTI)CTIUL746PLC 0
Hot wire ignition (HWI)1.0mmUL746PLC 4
flammabilityTest ConditionTest MethodCELANESE USA/101-73
UL flame retardant rating1.0mmUL94HB
3.0mmUL94HB
1.5mmUL94HB
physical property Test ConditionTest MethodCELANESE USA/101-73
DetergentResistanceISO188f4
UL749f3
Outdoor applicabilityUL746Cf1
elastomerTest ConditionTest MethodCELANESE USA/101-73
Tensile stress transverse flow rate100%应变,23°CASTMD4123.60 Mpa
Tearing Strength (MD)23°CASTMD62427.0 kN/m
CompressionSet4125°C,70hrASTMD395B37 %
Tensile stress transverse flow rate100%应变,23°CISO373.60 Mpa
Tensile Elongation(Across Flow)断裂,23°CISO37490 %
Compression permanent deformation 4125°C,70hrISO81537 %
Tensile strength - transverse flow rate断裂,23°CASTMD4128.80 Mpa
CompressionSet470°C,22hrASTMD395B28 %
Compression permanent deformation 470°C,22hrISO81528 %
tensile strength Break,23°CISO378.80 Mpa
TearStrength-AcrossFlow323°CISO34-127 kN/m
Tensile Elongation(Across Flow)断裂,23°CASTMD412490 %
agingTest ConditionTest MethodCELANESE USA/101-73
Change rate of tensile strength100°C,168hr,inIRM903OilASTMD471-30 %
23°C,168hr,inCyclohexaneASTMD47131 %
125°C,70hr,inIRM903OilISO1817-31 %
Changes in tensile stress during fracture23°C,168hr,inSulfuricAcid,98%ISO1817-27 %
Change rate of hardness of hardness tester 2ShoreA,100°C,168hr,inIRM903OilASTMD471-21
Changes in tensile stress during fracture23°C,168hr,inTrichloroethyleneISO181722 %
Change in Mass23°C,168hr,inMethylethylketoneASTMD471-24 %
Change rate of tensile strength23°C,168hr,inSodiumChloride,15%ISO18170.0 %
Change in Mass125°C,168hr,inIRM903OilISO181778 %
Change rate of ultimate elongation125°C,70hr,inIRM903OilASTMD471-47 %
Change rate of tensile strength100°C,168hr,inDeionizedWaterASTMD4711.0 %
Change rate of ultimate elongation23°C,168hr,inSodiumHydroxide,50%ASTMD4712.0 %
Change in Mass23.0°C,168hr,inTrichloroethyleneISO1817-6.0 %
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inIsopropylAlcoholASTMD471-1.0
Change rate of ultimate elongation23°C,168hr,inTrichloroethyleneASTMD47122 %
Changes in tensile stress during fracture23°C,168hr,inHydrochloricAcid,10%ISO18179.0 %
Change rate of ultimate elongation23°C,168hr,inIsopropylAlcoholASTMD47120 %
Changes in tensile stress during fracture23°C,168hr,inSodiumChloride,15%ISO1817-2.0 %
ChangeinShoreHardnessShoreA,23°C,168hr,inSodiumHydroxide,50%ISO18170.0
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inCyclohexaneASTMD471-16
ShoreA,23°C,168hr,inDetergent(Tide),2.5%ASTMD4710.0
Change in Mass125°C,168hr,inIRM903OilASTMD47178 %
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inSulfuricAcid,98%ASTMD4710.0
Change in Mass23°C,168hr,inTrichloroethyleneASTMD471-6.0 %
ChangeinShoreHardnessShoreA,23°C,168hr,inEthanol,95%ISO18170.0
Change in Mass23.0°C,168hr,inSodiumHydroxide,50%ISO1817-0.20 %
Change rate of ultimate elongation23°C,168hr,inMethylethylketoneASTMD47124 %
Change rate of tensile strength23°C,168hr,inEthanol,95%ISO1817-2.0 %
23°C,168hr,inEthanol,95%ASTMD471-2.0 %
23°C,168hr,inAceticAcidASTMD471-8.0 %
Changes in tensile stress during fracture23°C,168hr,inIsopropylAlcoholISO181720 %
23°C,168hr,inCyclohexaneISO181720 %
ChangeinShoreHardnessinAirShoreA,150°C,168hrISO1887.0
Changes in tensile stress during fracture23°C,168hr,inMethylethylketoneISO181724 %
Change in Mass23.0°C,168hr,inEthanol,95%ISO1817-0.10 %
Change rate of tensile strength in air150°C,168hrASTMD573-1.0 %
volume change125°C,70hr,在IRM903油中ISO181772 %
Change rate of tensile strength23°C,168hr,inSodiumHydroxide,50%ASTMD4713.0 %
ChangeinDurometerHardnessAirShoreA,150°C,168hrASTMD5737.0
Change rate of tensile strength125°C,70hr,inIRM903OilASTMD471-31 %
125°C,168hr,inIRM903OilASTMD471-31 %
Change in Mass23°C,168hr,inAceticAcidASTMD4714.0 %
23°C,168hr,inSodiumChloride,15%ASTMD4710.20 %
23.0°C,168hr,inMethylethylketoneISO1817-24 %
Change rate of tensile strength125°C,168hr,inIRM903OilISO1817-31 %
Change rate of ultimate elongation125°C,168hr,inIRM903OilASTMD471-58 %
Changes in tensile stress during fracture23°C,168hr,inDetergent(Tide),2.5%ISO18172.0 %
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inEthanol,95%ASTMD4710.0
ShoreA,23°C,168hr,inSodiumChloride,15%ASTMD4710.0
ChangeinShoreHardnessShoreA,23°C,168hr,inHydrochloricAcid,10%ISO1817-3.0
Change rate of ultimate elongation23°C,168hr,inHydrochloricAcid,10%ASTMD4719.0 %
Change rate of tensile strength23°C,168hr,inSulfuricAcid,98%ISO1817-17 %
Change rate of ultimate elongation23°C,168hr,inCyclohexaneASTMD47120 %
Change rate of tensile strength23°C,168hr,inSodiumHydroxide,50%ISO18173.0 %
Change rate of ultimate elongation100°C,168hr,inIRM903OilASTMD471-49 %
Change rate of tensile strength100°C,168hr,inDeionizedWaterISO18171.0 %
Change in Mass23.0°C,168hr,inAceticAcidISO18174.0 %
Change rate of tensile strength23°C,168hr,inDetergent(Tide),2.5%ASTMD4713.0 %
Changes in tensile stress during fracture125°C,70hr,inIRM903OilISO1817-47 %
Change rate of tensile strength in air150°C,168hrISO188-1.0 %
Change rate of hardness of hardness tester 2ShoreA,100°C,168hr,inDeionizedWaterASTMD471-2.0
Change in Mass100°C,168hr,inIRM903OilASTMD47166 %
Change rate of ultimate elongation100°C,168hr,inDeionizedWaterASTMD471-7.0 %
Change in Mass23.0°C,168hr,inSulfuricAcid,98%ISO18173.6 %
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inAceticAcidASTMD471-2.0
Change in Mass23°C,168hr,inSulfuricAcid,98%ASTMD4713.6 %
ChangeinShoreHardnessShoreA,23°C,168hr,inCyclohexaneISO1817-16
Change in Mass23.0°C,168hr,inSodiumChloride,15%ISO18170.20 %
Change rate of tensile strength23°C,168hr,inHydrochloricAcid,10%ISO181713 %
Change rate of ultimate elongation23°C,168hr,inEthanol,95%ASTMD4710.0 %
23°C,168hr,inAceticAcidASTMD471-4.0 %
Change rate of tensile strength23°C,168hr,inTrichloroethyleneISO181754 %
Changes in tensile stress during fracture23°C,168hr,inAceticAcidISO1817-4.0 %
Change in Mass23°C,168hr,inEthanol,95%ASTMD471-0.10 %
Change rate of ultimate elongation23°C,168hr,inDetergent(Tide),2.5%ASTMD4712.0 %
ChangeinShoreHardnessShoreA,100°C,168hr,inDeionizedWaterISO1817-2.0
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inTrichloroethyleneASTMD471-3.0
Change rate of tensile strength23°C,168hr,inIsopropylAlcoholASTMD47131 %
Change in Mass23°C,168hr,inSodiumHydroxide,50%ASTMD471-0.20 %
Change rate of tensile strength23°C,168hr,inTrichloroethyleneASTMD47154 %
Change in Mass23.0°C,168hr,inDetergent(Tide),2.5%ISO18170.60 %
Change rate of tensile strength23°C,168hr,inMethylethylketoneASTMD47147 %
ChangeinShoreHardnessShoreA,23°C,168hr,inSulfuricAcid,98%ISO18170.0
Change rate of ultimate elongation23°C,168hr,inSodiumChloride,15%ASTMD471-2.0 %
Change rate of tensile strength100°C,168hr,inIRM903OilISO1817-30 %
23°C,168hr,inAceticAcidISO1817-8.0 %
ChangeinShoreHardnessShoreA,23°C,168hr,inIsopropylAlcoholISO1817-1.0
Changes in tensile stress during fracture100°C,168hr,inIRM903OilISO1817-49 %
Change in Mass23.0°C,168hr,inHydrochloricAcid,10%ISO18170.20 %
23.0°C,168hr,inCyclohexaneISO1817-4.9 %
ChangeinShoreHardnessShoreA,23°C,168hr,inMethylethylketoneISO18170.0
Change in Mass100°C,168hr,inIRM903OilISO181766 %
Change rate of tensile strength23°C,168hr,inSulfuricAcid,98%ASTMD471-17 %
ChangeinShoreHardnessShoreA,23°C,168hr,inDetergent(Tide),2.5%ISO18170.0
Change in Mass100°C,168hr,inDeionizedWaterASTMD4713.6 %
Changes in tensile stress during fracture100°C,168hr,inDeionizedWaterISO1817-7.0 %
ChangeinShoreHardnessShoreA,125°C,168hr,inIRM903OilISO1817-23
Change in Mass23°C,168hr,inHydrochloricAcid,10%ASTMD4710.20 %
Change rate of hardness of hardness tester 2ShoreA,125°C,168hr,inIRM903OilASTMD471-23
Change rate of ultimate elongation23°C,168hr,inSulfuricAcid,98%ASTMD471-27 %
Changes in tensile stress during fracture23°C,168hr,inSodiumHydroxide,50%ISO18172.0 %
ChangeinShoreHardnessShoreA,23°C,168hr,inAceticAcidISO1817-2.0
Change rate of ultimate elongation in air150°C,168hrASTMD573-3.0 %
ChangeinShoreHardnessShoreA,23°C,168hr,inTrichloroethyleneISO1817-3.0
Change rate of tensile strength23°C,168hr,inDetergent(Tide),2.5%ISO18173.0 %
23°C,168hr,inHydrochloricAcid,10%ASTMD47113 %
Changes in tensile stress during fracture23°C,168hr,inEthanol,95%ISO18170.0 %
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inMethylethylketoneASTMD4710.0
Change rate of tensile strength23°C,168hr,inMethylethylketoneISO181747 %
23°C,168hr,inSodiumChloride,15%ASTMD4710.0 %
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inHydrochloricAcid,10%ASTMD471-3.0
Change in Mass23°C,168hr,inCyclohexaneASTMD471-4.9 %
ChangeinShoreHardnessShoreA,23°C,168hr,inSodiumChloride,15%ISO18170.0
ShoreA,100°C,168hr,inIRM903OilISO1817-21
Change rate of hardness of hardness tester 2ShoreA,23°C,168hr,inSodiumHydroxide,50%ASTMD4710.0
Change in Mass100°C,168hr,inDeionizedWaterISO18173.6 %
Changes in tensile stress during fracture125°C,168hr,inIRM903OilISO1817-58 %
Change in Mass23°C,168hr,inDetergent(Tide),2.5%ASTMD4710.60 %
Change rate of tensile strength23°C,168hr,inIsopropylAlcoholISO181731 %
23°C,168hr,inCyclohexaneISO181731 %
Change in Mass23.0°C,168hr,inIsopropylAlcoholISO1817-13 %
volume change125°C,70hr,在IRM903油中ASTMD47172 %
Change in Mass23°C,168hr,inIsopropylAlcoholASTMD471-13 %
Thermal performanceTest ConditionTest MethodCELANESE USA/101-73
brittle temperatureISO812-60.0 °C
RTI Str1.5mmUL74690.0 °C
RTI ElecUL74690.0 °C
brittle temperatureASTMD746-60.0 °C
RTI Str3.0mmUL74695.0 °C
1.0mmUL74690.0 °C

Contact Us

Get App

Top