Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PPSU R-5100 BK SOLVAY USA
RADEL® 
Medical devices、Electrical applications、household electrical appl
Resistance to stress crac、Thermal stability、High impact resistance
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodSOLVAY USA/R-5100 BK
Impact strength of cantilever beam gapASTM D256NoBreak
ASTM D256690 J/m
ASTM D1822399 kJ/m²
Mechanical propertiesTest ConditionTest MethodSOLVAY USA/R-5100 BK
Tensile modulusASTM D6382340 Mpa
elongation断裂ASTM D63860 %
Compression ModulusASTM D6951730 Mpa
elongation屈服ASTM D6387.2 %
bending strength屈服ASTM D79091.0 Mpa
tensile strength 断裂ASTM D63869.6 Mpa
shear strengthASTM D73262.7 Mpa
tensile strength 屈服ASTM D63869.6 Mpa
Flexural modulusASTM D7902410 Mpa
compressive strengthASTM D69598.9 Mpa
Poisson's ratioASTME1320.42
Electrical performanceTest ConditionTest MethodSOLVAY USA/R-5100 BK
dielectric constant60HzASTM D1503.44
Volume resistivityASTM D2579E+15 ohms·cm
dielectric constant1kHzASTM D1503.40
dielectric strengthASTM D14914 KV/mm
optical performance Test ConditionTest MethodSOLVAY USA/R-5100 BK
refractive indexASTM D5421.672
flammabilityTest ConditionTest MethodSOLVAY USA/R-5100 BK
UL flame retardant rating0.75mmUL 94V-0
Limiting Oxygen IndexASTM D286338 %
physical property Test ConditionTest MethodSOLVAY USA/R-5100 BK
Shrinkage rateMDASTM D9550.70 %
Water absorption rate24hrASTM D5700.37 %
densityASTM D7921.30 g/cm³
melt mass-flow rateASTM D123814to20 g/10min
Thermal performanceTest ConditionTest MethodSOLVAY USA/R-5100 BK
Heat distortion temperature1.8MPa,未退火,HDTASTM D648207 °C
0.45MPa,未退火,HDTASTM D648214 °C
thermal conductivityASTMC1770.35 W/m/K
Linear coefficient of thermal expansionMDASTM D6965.6E-05 cm/cm/°C
Glass Transition TemperatureASTME1356220 °C

Contact Us

Get App

Top