Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

LCP 7130 NC010 CELANESE USA
VECTRA®
Automotive Applications,Home appliance components,Medical/nursing supplies
enhance,Glass fiber reinforced,High impact resistance,heat-resisting,Filler: Glass fiber reinf,30%,Filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
thermal performance | Test Condition | Test Method | CELANESE USA/7130 NC010 |
---|---|---|---|
Glass transition temperature | ISO 11357-2 | 120 °C | |
Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 310 °C |
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 6.2E-05 cm/cm/°C |
MD | ISO 11359-2 | 3E-06 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 352 °C |
mechanical properties | Test Condition | Test Method | CELANESE USA/7130 NC010 |
---|---|---|---|
Bending modulus | 23°C | ISO 178 | 13000 Mpa |
bending strength | 23°C | ISO 178 | 210 Mpa |
Tensile modulus | ISO 527-2/1A/1 | 17000 Mpa | |
Tensile strain | Break | ISO 527-2/1A/5 | 1.5 % |
tensile strength | Break | ISO 527-2/1A/5 | 150 Mpa |
Electrical performance | Test Condition | Test Method | CELANESE USA/7130 NC010 |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | V | |
Dielectric strength | IEC 60243-1 | 45 KV/mm | |
Dissipation factor | 1MHz | IEC 60250 | 0.030 |
100Hz | IEC 60250 | 0.014 | |
Relative permittivity | 100Hz | IEC 60250 | 4.10 |
1MHz | IEC 60250 | 3.70 | |
Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | CELANESE USA/7130 NC010 |
---|---|---|---|
Shrinkage rate | MD | ISO 294-4 | 0.010 % |
TD | ISO 294-4 | 0.60 % |
impact performance | Test Condition | Test Method | CELANESE USA/7130 NC010 |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 22 kJ/m² |
23°C | ISO 179/1eU | 30 kJ/m² | |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 30 kJ/m² |
flammability | Test Condition | Test Method | CELANESE USA/7130 NC010 |
---|---|---|---|
Extreme Oxygen Index | ISO 4589-2 | 45 % | |
UL flame retardant rating | 0.40mm | UL 94 | V-0 |