Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PEEK MOTIS™ LV Invibio Inc.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Invibio Inc./MOTIS™ LV |
---|---|---|---|
Impact strength of cantilever beam gap | ISO 180 | 5.5 kJ/m² | |
Suspended wall beam without notch impact strength | ISO 180 | 30 kJ/m² |
hardness | Test Condition | Test Method | Invibio Inc./MOTIS™ LV |
---|---|---|---|
Rockwell hardness | M级 | ASTM D785 | 105 |
Mechanical properties | Test Condition | Test Method | Invibio Inc./MOTIS™ LV |
---|---|---|---|
Compression Modulus | ISO 604 | 12000 MPa | |
Tensile modulus | ISO 527-2 | 15000 MPa | |
shear modulus | ISO 15310 | 2200 MPa | |
tensile strength | 屈服 | ISO 527-2 | 155 MPa |
Tensile strain | 断裂2 | ISO 527-2 | 2.8 % |
Poisson's ratio | ASTME132 | 0.41 | |
bending strength | --2 | ISO 178 | 164 MPa |
Tensile strain | 断裂 | ISO 527-2 | 2.0 % |
compression stress | ISO 604 | 200 MPa | |
Flexural modulus | -- | ISO 178 | 12500 MPa |
--2 | ISO 178 | 6400 MPa | |
bending strength | -- | ISO 178 | 230 MPa |
tensile strength | 屈服2 | ISO 527-2 | 98.0 MPa |
shear strength | ASTM D732 | 94.0 MPa |
Filling analysis | Test Condition | Test Method | Invibio Inc./MOTIS™ LV |
---|---|---|---|
MeltViscosity | 内部方法 | 0.370 kPa |
physical property | Test Condition | Test Method | Invibio Inc./MOTIS™ LV |
---|---|---|---|
Water absorption rate | 23°C,24hr | ISO 62 | 0.50 % |
Shrinkage rate | TD:210°C | 0.90 % | |
density | ISO 1183 | 1.42 g/cm³ | |
Shrinkage rate | MD:210°C | 0.10 % |
Thermal performance | Test Condition | Test Method | Invibio Inc./MOTIS™ LV |
---|---|---|---|
melting temperature | 343 °C | ||
Linear coefficient of thermal expansion | MD:--3 | ASTM D696 | 1.2E-05 cm/cm/°C |
MD:--4 | ASTM D696 | 1.5E-05 cm/cm/°C |