ABS Sicoflex 2000HG Entec Polymers
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Entec Polymers/Sicoflex 2000HG |
---|---|---|---|
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 5.0 kJ/m² |
23°C | ISO 180/1A | 15 kJ/m² |
Electrical performance | Test Condition | Test Method | Entec Polymers/Sicoflex 2000HG |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 1 | |
Volume resistivity | IEC 60093 | 1E+13 ohms·cm | |
dielectric strength | 1.00mm,在油中 | IEC 60243-1 | 25 kV/mm |
Surface Resistivity | IEC 60093 | 1E+14 ohms |
Mechanical properties | Test Condition | Test Method | Entec Polymers/Sicoflex 2000HG |
---|---|---|---|
tensile strength | 断裂 | ISO 527-2 | 30.0 MPa |
Tensile strain | 断裂 | ISO 527-2 | 20 % |
tensile strength | 屈服 | ISO 527-2 | 38.0 MPa |
Flexural modulus | ISO 178 | 2600 MPa |
flammability | Test Condition | Test Method | Entec Polymers/Sicoflex 2000HG |
---|---|---|---|
Hot filament ignition temperature | 1.2mm | IEC 60695-2-13 | 750 °C |
UL flame retardant rating | 3.2mm | UL 94 | V-0 |
Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 960 °C |
UL flame retardant rating | 1.6mm | UL 94 | V-0 |
physical property | Test Condition | Test Method | Entec Polymers/Sicoflex 2000HG |
---|---|---|---|
Shrinkage rate | ISO 2577 | 0.30to0.50 % | |
density | ISO 1183 | 1.18 g/cm³ | |
melt mass-flow rate | 220°C/10.0kg | ISO 1133 | 35 g/10min |
Thermal performance | Test Condition | Test Method | Entec Polymers/Sicoflex 2000HG |
---|---|---|---|
vicat | -- | ISO 306/A50 | 95.0 °C |
Heat distortion temperature | 1.8MPa,退火,HDT | ISO 75-2/A | 78.0 °C |
vicat | -- | ISO 306/B50 | 84.0 °C |