Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA6 Plaslube® PA6 GF10 TL10 Techmer Polymer Modifiers
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Impact resistanceTest ConditionTest MethodTechmer Polymer Modifiers/Plaslube® PA6 GF10 TL10
Impact strength of cantilever beam gap23°C,3.18mmASTM D25664 J/m
hardnessTest ConditionTest MethodTechmer Polymer Modifiers/Plaslube® PA6 GF10 TL10
Rockwell hardnessR级ASTM D785117
Mechanical propertiesTest ConditionTest MethodTechmer Polymer Modifiers/Plaslube® PA6 GF10 TL10
elongation断裂ASTM D6383.5 %
tensile strength 断裂ASTM D63875.8 MPa
Flexural modulusASTM D7903590 MPa
bending strengthASTM D790103 MPa
Electrical performanceTest ConditionTest MethodTechmer Polymer Modifiers/Plaslube® PA6 GF10 TL10
Volume resistivityASTM D2573E+14 ohms·cm
dielectric strengthASTM D14917 kV/mm
flammabilityTest ConditionTest MethodTechmer Polymer Modifiers/Plaslube® PA6 GF10 TL10
UL flame retardant ratingUL 94HB
physical property Test ConditionTest MethodTechmer Polymer Modifiers/Plaslube® PA6 GF10 TL10
Water absorption rate24hrASTM D5701.1 %
densityASTM D7921.33 g/cm³
Shrinkage rateMD:3.18mmASTM D9550.60 %
Thermal performanceTest ConditionTest MethodTechmer Polymer Modifiers/Plaslube® PA6 GF10 TL10
Heat distortion temperature1.8MPa,未退火,HDTASTM D648204 °C
Linear coefficient of thermal expansionMDASTM D6965.4E-05 cm/cm/°C