Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA66 C216 SOLVAY FRANCE
TECHNYL® 
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Electrical performanceTest ConditionTest MethodSOLVAY FRANCE/C216
Surface Resistivity---IEC 930.1 E14.ohm
dielectric constant1MHzIEC 2503.8 ---
Volume resistivity---IEC 9310 E14.ohm.cm
Compared to the Leakage Traceability Index (CTI)---IEC 112550 V
Dielectric loss1MHzIEC 2500.02 ---
Mechanical propertiesTest ConditionTest MethodSOLVAY FRANCE/C216
Charpy Notched Impact Strength---ISO 179-19935.5 kJ/m²
Impact strength of cantilever beam gap---ISO 1805 kJ/m²
Impact strength of simply supported beam without notch---ISO 179-199342 kJ/m²
elongation at break---ISO 5274 %
Tensile modulus---ISO 5276100 Mpa
elongation at break---ISO 527120 Mpa
physical property Test ConditionTest MethodSOLVAY FRANCE/C216
Water absorption rate在23℃,24小时ISO 621.15 %
Thermal performanceTest ConditionTest MethodSOLVAY FRANCE/C216
Glow wire combustion index (GWFI)1.6mmIEC 695-2-1650 °C
combustibility1.6mmISO 1210UL 94HB V
melting temperature---ISO 3146C222 °C
Heat distortion temperature1.8MPa,HDTISO 179-1993180 °C
Linear coefficient of thermal expansion23℃-85℃ISO 75-24.2 E-5/℃

Contact Us

Get App

Top