Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 C216 SOLVAY FRANCE
TECHNYL®
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Electrical performance | Test Condition | Test Method | SOLVAY FRANCE/C216 |
---|---|---|---|
Surface Resistivity | --- | IEC 93 | 0.1 E14.ohm |
dielectric constant | 1MHz | IEC 250 | 3.8 --- |
Volume resistivity | --- | IEC 93 | 10 E14.ohm.cm |
Compared to the Leakage Traceability Index (CTI) | --- | IEC 112 | 550 V |
Dielectric loss | 1MHz | IEC 250 | 0.02 --- |
Mechanical properties | Test Condition | Test Method | SOLVAY FRANCE/C216 |
---|---|---|---|
Charpy Notched Impact Strength | --- | ISO 179-1993 | 5.5 kJ/m² |
Impact strength of cantilever beam gap | --- | ISO 180 | 5 kJ/m² |
Impact strength of simply supported beam without notch | --- | ISO 179-1993 | 42 kJ/m² |
elongation at break | --- | ISO 527 | 4 % |
Tensile modulus | --- | ISO 527 | 6100 Mpa |
elongation at break | --- | ISO 527 | 120 Mpa |
physical property | Test Condition | Test Method | SOLVAY FRANCE/C216 |
---|---|---|---|
Water absorption rate | 在23℃,24小时 | ISO 62 | 1.15 % |
Thermal performance | Test Condition | Test Method | SOLVAY FRANCE/C216 |
---|---|---|---|
Glow wire combustion index (GWFI) | 1.6mm | IEC 695-2-1 | 650 °C |
combustibility | 1.6mm | ISO 1210UL 94 | HB V |
melting temperature | --- | ISO 3146C | 222 °C |
Heat distortion temperature | 1.8MPa,HDT | ISO 179-1993 | 180 °C |
Linear coefficient of thermal expansion | 23℃-85℃ | ISO 75-2 | 4.2 E-5/℃ |
Contact Us
Get App
Top