Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PFA MFA 1041 SOLVAY USA
HYFLON® 
Electric wire、Cable Applications
Flame retardant、Conductive
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Other performanceTest ConditionTest MethodSOLVAY USA/MFA 1041
latent heatJ/gNFPA 259 970
UL flame retardant ratingUL 94V-0
Basic performanceTest ConditionTest MethodSOLVAY USA/MFA 1041
melt mass-flow rate372℃/5.0kgASTM D-123825 g/10min
Mechanical propertiesTest ConditionTest MethodSOLVAY USA/MFA 1041
Charpy Notched Impact StrengthASTM D-256No Break
tensile strength 23℃,断裂ASTM D-1708>20 MPa
elongation at break23℃ASTM D-1708>280 %
Tensile modulus23℃ASTM D-1708550 MPa
Shore hardnessShore DASTM D-224058
Electrical performanceTest ConditionTest MethodSOLVAY USA/MFA 1041
Dissipation Factor23℃,9E+8HzASTM D-1500.0002
dielectric constant23℃,1E+6HzASTM D-1502
23℃,9E+8HzASTM D-1502
Volume resistivityASTM D-257>1.0E+17 ohm·cm
Dissipation Factor23℃,2E+9HzASTM D-1500.0002
23℃,1E+6HzASTM D-1500.0002
Surface ResistivityASTM D-257>1.0E+17 ohms
compressive strengthASTM D-14938 kV/mm
dielectric constant23℃,2E+9HzASTM D-1502
Thermal performanceTest ConditionTest MethodSOLVAY USA/MFA 1041
melting temperatureASTM D-3307280-290
specific heat23℃DSC1000 J/kg/℃
Linear coefficient of thermal expansionFlowASTM D-6960.00016 cm/cm/℃
thermal conductivity40℃ASTM C-1770.2 W/m/K
heat of fusionDSC18-26 J/g