plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PFA MFA 1041 SOLVAY USA
HYFLON® 
Electric wire,Cable Applications
Flame retardant,Conductive
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Other performanceTest ConditionTest MethodSOLVAY USA/MFA 1041
latent heatJ/gNFPA 259 970
UL flame retardant ratingUL 94V-0
Basic PerformanceTest ConditionTest MethodSOLVAY USA/MFA 1041
melt mass-flow rate372℃/5.0kgASTM D-123825 g/10min
thermal performanceTest ConditionTest MethodSOLVAY USA/MFA 1041
Linear coefficient of thermal expansionFlowASTM D-6960.00016 cm/cm/℃
Melting heatDSC18-26 J/g
Melting temperatureASTM D-3307280-290
specific heat23℃DSC1000 J/kg/℃
thermal conductivity40℃ASTM C-1770.2 W/m/K
mechanical propertiesTest ConditionTest MethodSOLVAY USA/MFA 1041
Charpy Notched Impact StrengthASTM D-256No Break
Elongation at Break23℃ASTM D-1708>280 %
Shore hardnessShore DASTM D-224058
Tensile modulus23℃ASTM D-1708550 MPa
tensile strength23℃,BreakASTM D-1708>20 MPa
Electrical performanceTest ConditionTest MethodSOLVAY USA/MFA 1041
compressive strengthASTM D-14938 kV/mm
Dielectric constant23℃,9E+8HzASTM D-1502
23℃,1E+6HzASTM D-1502
23℃,2E+9HzASTM D-1502
Dissipation factor23℃,1E+6HzASTM D-1500.0002
23℃,9E+8HzASTM D-1500.0002
23℃,2E+9HzASTM D-1500.0002
Surface resistivityASTM D-257>1.0E+17 ohms
Volume resistivityASTM D-257>1.0E+17 ohm·cm