Material Comparison
Add Comparison Model
Select Products for Comparison (1/4)
Highlight Differences
Hide Same
Product Name / Manufacturer / Model
Grade
Certificates
Reference Price
| mechanical properties | Test Condition | Test Method | HYOSUNG KOREA/J842 |
|---|---|---|---|
| Rockwell hardness | ASTM D-785 | 90 R-Scale | |
| Impact strength of cantilever beam gap | 23℃ | ASTM D-256 | 7.0 kg.cm/cm |
| -20℃ | ASTM D-256 | 4.0 kg.cm/cm | |
| tensile strength | Yield | ASTM D638 | 27.5 Mpa |
| Impact strength of cantilever beam gap | 0℃ | ASTM D-256 | 4.5 kg.cm/cm |
| Bending modulus | ASTM D790 | 1470 Mpa | |
| Charpy Notched Impact Strength | ASTM D256/ISO 179 | 7.0 kg·cm/cm(J/M)ft·lb/in | |
| elongation | ASTM D-638 | 200 % | |
| bending strength | ASTM D790/ISO 178 | 15000 kg/cm²(MPa)[Lb/in²] | |
| Bending modulus | ASTM D-790 | 15000 kg/cm | |
| tensile strength | ASTM D-638 | 290 kg/cm | |
| other | Test Condition | Test Method | HYOSUNG KOREA/J842 |
| purpose | 洗衣机附件家庭用品 | ||
| characteristic | 高冲击高流动UL94HB | ||
| flammability | Test Condition | Test Method | HYOSUNG KOREA/J842 |
| UL flame retardant rating | UL 94 | HB | |
| thermal performance | Test Condition | Test Method | HYOSUNG KOREA/J842 |
| Vicat softening temperature | ASTM D-1525 | 150 °C | |
| Hot deformation temperature | HDT | ASTM D-648 | 120 °C |
| 0.45MPa,Unannealed | ASTM D648 | 120 °C | |
| hardness | Test Condition | Test Method | HYOSUNG KOREA/J842 |
| Rockwell hardness | R-Scale | ASTM D785 | 85 |
| Basic Performance | Test Condition | Test Method | HYOSUNG KOREA/J842 |
| melt mass-flow rate | ASTM D-1238 | 45 g/10min | |
| Physical properties | Test Condition | Test Method | HYOSUNG KOREA/J842 |
| melt mass-flow rate | ASTM D1238/ISO 1133 | 45 g/10min | |
| 230°C/2.16kg | ASTM D1238 | 45 g/10min |