PC 3412R SABIC INNOVATIVE US
LEXAN™ 
Automotive sector
Flame retardant,enhance,Glass fiber reinforced
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

hardnessTest ConditionTest MethodSABIC INNOVATIVE US/3412R
Rockwell hardnessM-SaleASTM D78591
R-SaleASTM D785122
thermal performanceTest ConditionTest MethodSABIC INNOVATIVE US/3412R
Hot deformation temperature1.8MPa,Unannealed,6.40mmASTM D648146 °C
0.45MPa,Unannealed,6.40mmASTM D648149 °C
Linear coefficient of thermal expansionMD:-40to95°CASTME8312.7E-05 cm/cm/°C
RTI ElecUL 746130 °C
RTI ImpUL 746130 °C
RTI StrUL 746130 °C
specific heatASTMC3511170 J/kg/°C
thermal conductivityASTMC1770.21 W/m/K
Vicat softening temperatureASTM D15255166 °C
mechanical propertiesTest ConditionTest MethodSABIC INNOVATIVE US/3412R
Bending modulus50.0mmSpanASTM D7905520 Mpa
bending strengthYield,50.0mmSpanASTM D790131 Mpa
elongationBreakASTM D6385.0 %
Taber abraser1000Cycles,1000g,CS-17WheelASTM D104417.0 mg
tensile strengthBreakASTM D638110 Mpa
Electrical performanceTest ConditionTest MethodSABIC INNOVATIVE US/3412R
Arc resistanceASTM D495PLC7
Compared to the anti leakage trace indexCTIUL 746PLC 5
Dielectric constant1MHzASTM D1503.13
50HzASTM D1503.17
60HzASTM D1503.17
Dielectric strength3.20mm,inAirASTM D14919 KV/mm
Dissipation factor1MHzASTM D1507.3E-03
60HzASTM D1509E-04
50HzASTM D1509E-04
High arc combustion indexHAIUL 746PLC 4
High voltage arc tracing rateHVTRUL 746PLC 3
Hot wire ignitionHWIUL 746PLC 0
Volume resistivityASTM D257>1.0E+17 ohms·cm
Physical propertiesTest ConditionTest MethodSABIC INNOVATIVE US/3412R
densityASTM D7921.36 g/cm³
melt mass-flow rate300°C/1.2kgASTM D12384.3 g/10min
Shrinkage rateMD:3.20mmInternal Method0.10-0.30 %
Specific volumeASTM D7920.741 cm³/g
Water absorption rate24hrASTM D5700.16 %
Equilibrium,23°CASTM D5700.29 %
impact performanceTest ConditionTest MethodSABIC INNOVATIVE US/3412R
Dart impact23°CASTM D30295.42 J
Impact strength of cantilever beam gap23°CASTM D256110 J/m
23°CASTM D48121000 J/m
ASTM D182263.0 kJ/m²
flammabilityTest ConditionTest MethodSABIC INNOVATIVE US/3412R
UL flame retardant rating3.0mmUL 94V-0
1.5mmUL 94V-1