Material Comparison
Add Comparison Model
Select Products for Comparison (1/4)
Highlight Differences
Hide Same
Product Name / Manufacturer / Model
Grade
Reference Price
| mechanical properties | Test Condition | Test Method | TECHNO JAPAN/H814 |
|---|---|---|---|
| Rockwell hardness | ASTM D-785 | 114 R scale | |
| Tensile stress | Yield | ASTM D-638 | 49.0 Mpa |
| Impact strength of cantilever beam gap | ASTM D-256 | 88.0 J/m | |
| bending strength | ASTM D-790 | 75.5 Mpa | |
| Bending modulus | ASTM D-790 | 2350 Mpa | |
| thermal performance | Test Condition | Test Method | TECHNO JAPAN/H814 |
| Combustibility | ALL | UL 94 | HB |
| Hot deformation temperature | 0.45MPa,Unannealed | ASTM D-648 | 96.0 °C |
| Physical properties | Test Condition | Test Method | TECHNO JAPAN/H814 |
| Shrinkage rate | ISO 294-4 | 0.40-0.60 % | |
| Basic Performance | Test Condition | Test Method | TECHNO JAPAN/H814 |
| melt mass-flow rate | 240℃/10.0kg | ISO 1133 | 14 g/10min |