Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PSU E3010 BASF GERMANY
Ultrason®E  
Electrical field,Electronic field,Household appliances,Household appliances,Electric wire,Cable,Automotive sector,Bottle cap
High toughness,Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | BASF GERMANY/E3010 | 
|---|---|---|---|
| Ball Pressure Test | ISO 2039-1 | 154 Mpa | 
| thermal performance | Test Condition | Test Method | BASF GERMANY/E3010 | 
|---|---|---|---|
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | 207 °C | 
| Linear coefficient of thermal expansion | MD | 5.2E-05 cm/cm/°C | |
| RTI Elec | 1.6mm | UL 746 | 180 °C | 
| 3.0mm | UL 746 | 180 °C | |
| RTI Imp | 1.6mm | UL 746 | 180 °C | 
| 3.0mm | UL 746 | 180 °C | |
| RTI Str | 3.0mm | UL 746 | 190 °C | 
| 1.6mm | UL 746 | 190 °C | 
| mechanical properties | Test Condition | Test Method | BASF GERMANY/E3010 | 
|---|---|---|---|
| Tensile modulus | 23°C | ISO 527-2 | 2650 Mpa | 
| Tensile strain | Yield,23°C | ISO 527-2 | 6.9 % | 
| tensile strength | Yield,23°C | ISO 527-2 | 85.0 Mpa | 
| Electrical performance | Test Condition | Test Method | BASF GERMANY/E3010 | 
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | PLC 4 | |
| Dielectric constant | 1MHz | IEC 60250 | 3.80 | 
| 100Hz | IEC 60250 | 3.90 | |
| Dielectric strength | IEC 60243-1 | 34 KV/mm | |
| Dissipation factor | 1MHz | IEC 60250 | 0.014 | 
| 100Hz | IEC 60250 | 1.7E-03 | |
| Surface resistivity | IEC 60093 | >1.0E+15 ohms | |
| Volume resistivity | IEC 60093 | >1.0E+13 ohms·cm | 
| Physical properties | Test Condition | Test Method | BASF GERMANY/E3010 | 
|---|---|---|---|
| density | ISO 1183 | 1.37 g/cm³ | |
| Melt Volume Flow Rate (MVR) | 360°C/10.0kg | ISO 1133 | 35.0 cm3/10min | 
| Shrinkage rate | MD | ISO 294-4 | 0.85 % | 
| TD | ISO 294-4 | 0.90 % | |
| Water absorption rate | Equilibrium,23°C,50%RH | ISO 62 | 0.80 % | 
| Saturation,23°C | ISO 62 | 2.2 % | 
| impact performance | Test Condition | Test Method | BASF GERMANY/E3010 | 
|---|---|---|---|
| Charpy Notched Impact Strength | -30°C | ISO 179 | 8.0 kJ/m² | 
| 23°C | ISO 179 | 8.0 kJ/m² | |
| Impact strength of cantilever beam gap | 23°C | ISO 180 | 8.0 kJ/m² | 
| -30°C | ISO 180 | 8.0 kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179 | NoBreak | 
| 23°C | ISO 179 | NoBreak | 
| flammability | Test Condition | Test Method | BASF GERMANY/E3010 | 
|---|---|---|---|
| UL flame retardant rating | 3.0mm | UL 94 | V-0 | 
| 1.6mm | UL 94 | V-0 |