Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PI, TS VTEC™ GF63 RBI, Inc.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | RBI, Inc./VTEC™ GF63 |
---|---|---|---|
Impact strength of cantilever beam gap | 24°C | ASTM D256 | 800 J/m |
Supplementary Information | Test Condition | Test Method | RBI, Inc./VTEC™ GF63 |
---|---|---|---|
Thermal Gravimetric Analysis | 500°C | Norecordableweightloss | |
Thermal-oxidativeDeterioration | 182°C | 0.20 % | |
Space stability, shrinkage | 246°C | 0.0 % |
hardness | Test Condition | Test Method | RBI, Inc./VTEC™ GF63 |
---|---|---|---|
Barcol Hardness | ASTM D2583 | 75 |
Mechanical properties | Test Condition | Test Method | RBI, Inc./VTEC™ GF63 |
---|---|---|---|
tensile strength | 246°C | ASTM D638 | 82.7 MPa |
CompressiveStrength-Open-Hole | 246°C | ASTM D648 | Passed |
tensile strength | 24°C | ASTM D638 | 75.8 MPa |
Flexural modulus | 24°C | ASTM D790 | 15900 MPa |
246°C | ASTM D790 | 15200 MPa | |
204°C | ASTM D790 | 14500 MPa | |
bending strength | 24°C | ASTM D790 | 207 MPa |
tensile strength | 204°C | ASTM D638 | 75.8 MPa |
bending strength | 204°C | ASTM D790 | 214 MPa |
246°C | ASTM D790 | 221 MPa |
physical property | Test Condition | Test Method | RBI, Inc./VTEC™ GF63 |
---|---|---|---|
Water absorption rate | 饱和,24°C | ASTM D570 | <0.10 % |
density | ASTM D792 | 1.87 g/cm³ |
Thermal performance | Test Condition | Test Method | RBI, Inc./VTEC™ GF63 |
---|---|---|---|
Glass Transition Temperature | 270 °C | ||
Linear coefficient of thermal expansion | MD:75°C | ASTM D696 | 1.4E-05 cm/cm/°C |
Contact Us
Get App
Top