Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC FR3010 012881 COVESTRO SHANGHAI
Makrolon®
Medical packaging
Chemical resistance、Flame retardant、heat-resisting
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Mechanical properties | Test Condition | Test Method | COVESTRO SHANGHAI/FR3010 012881 |
---|---|---|---|
Impact strength of cantilever beam gap | 23°C | ISO 180/1A | 35 kJ/m² |
Tensile modulus | 23°C | ISO 527-2 | 2700 Mpa |
elongation at break | 23°C | ISO 527-2 | >50 % |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 10 kJ/m² |
tensile strength | 23°C | ISO 527-2 | 60 Mpa |
Electrical performance | Test Condition | Test Method | COVESTRO SHANGHAI/FR3010 012881 |
---|---|---|---|
Dissipation Factor | 相对漏电起痕指数 | IEC 60112 | 350 V |
dielectric strength | IEC 60243-1 | 35 KV/mm | |
dielectric constant | 23°C | IEC 60250 | 3.1 1MHz |
Surface Resistivity | IEC 60093 | 1E+16 Ω.cm | |
Dissipation Factor | 23°C | IEC 60250 | 7E-03 1MHz |
Volume resistivity | IEC 60093 | 1E+16 Ω.cm |
Flame retardant performance | Test Condition | Test Method | COVESTRO SHANGHAI/FR3010 012881 |
---|---|---|---|
Relative temperature of heating wire | 1.00mm | IEC 60695-2-13 | 960 °C |
GWIT | 2.20mm | IEC 60695-2-12 | 850 °C |
UL flame retardant rating | UL -94 | V-0.5VB 2.20mm | |
Relative temperature of heating wire | 2.20mm | IEC 60695-2-13 | 960 °C |
UL flame retardant rating | UL -94 | V-0.5VA 3.00mm | |
UL -94 | 1.00mm | ||
GWIT | 3.00mm | IEC 60695-2-12 | 850 °C |
Relative temperature of heating wire | 3.00mm | IEC 60695-2-13 | 960 °C |
GWIT | 1.00mm | IEC 60695-2-12 | 850 °C |
Relative temperature of heating wire | 1.50mm | IEC 60695-2-13 | 960 °C |
UL flame retardant rating | UL -94 | V-0 1.50mm | |
UL -94 | 0.75mm | ||
GWIT | 1.50mm | IEC 60695-2-12 | 850 °C |
physical property | Test Condition | Test Method | COVESTRO SHANGHAI/FR3010 012881 |
---|---|---|---|
Water absorption rate | (23°C,24hr) | ISO 62 | 0.50 % |
Shrinkage rate | MD2.0mm | ISO 294-4 | 0.60 % |
melt mass-flow rate | 240℃/5.0Kg | ISO 1133 | 25 cm3/10min |
Water absorption rate | (23°C,50RH) | ISO 62 | 0.20 % |
Shrinkage rate | TD2.0mm | ISO 294-4 | 0.60 % |
Thermal performance | Test Condition | Test Method | COVESTRO SHANGHAI/FR3010 012881 |
---|---|---|---|
Heat distortion temperature | 1.80MPa退火,HDT | ISO 75-2/Af | 90 °C |
vicat | ISO 306/B50 | 106 °C | |
Linear coefficient of thermal expansion | MD | ISO 11359-2 | 7.6E-05 cm/cm/°C |
Heat distortion temperature | 0.45MPa未退火,HDT | ISO 75-2/Bf | 100 °C |
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 8E-05 cm/cm/°C |