Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA12 LV-3H EMS-CHEMIE SWITZERLAND
Grilamid®
Automotive sector,Shell,electrical machinery,Electrical field,Electronic field,chip,machine,Mechanical components
Weather resistance,Chemical resistance,wear resistant,dimensional stability ,Low temperature impact re,Gas barrier,Glass fiber reinforced
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| Basic Performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/LV-3H |
|---|---|---|---|
| density | dry | ISO 1183 | 1.22 dry |
| Water absorption rate | 23℃ | ISO 62 | 1.1 % |
| 23℃/50%rh | ISO 62 | 0.6 % |
| thermal performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/LV-3H |
|---|---|---|---|
| Hot deformation temperature | 1.80MPa,dry | ISO 75 | 160 °C |
| 8.00MPa,dry | ISO 75 | 160 °C | |
| Linear coefficient of thermal expansion | 23-55℃,dry(Across Flow) | ISO 11359 | 1.5 |
| 23-55℃,dry | ISO 11359 | 0.2 | |
| Maximum operating temperature | long term,dry | ISO 2578 | 90-120 °C |
| short term,dry | ISO 2578 | 150 °C | |
| Melting temperature | DSC,dry | ISO 11357 | 178 °C |
| UL flame retardant rating | 0.8mm | ISO 1210 | HB |
| mechanical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/LV-3H |
|---|---|---|---|
| Elongation at Break | 5mm/min,cond | ISO 527 | 8 % |
| Impact strength of cantilever beam gap | Charpy,23℃,cond | ISO 179/2-1eA | 20 KJ/m |
| Charpy,23℃,cond | ISO 179/2-1eU | 80 KJ/m | |
| Charpy,-30℃,cond | ISO 179/2-1eU | 80 KJ/m | |
| Charpy,-30℃,cond | ISO 179/2-1eA | 15 KJ/m | |
| Shore hardness | cond | ISO 2039-1 | 77 Mpa |
| Tensile modulus | 1mm/min,cond | ISO 527 | 6000 Mpa |
| tensile strength | 5mm/min,cond,Break | ISO 527 | 105 Mpa |
| Electrical performance | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/LV-3H |
|---|---|---|---|
| Arc resistance | cond | IEC 60112 | 600 |
| Dielectric strength | dry,cond | IEC 60243-1 | 35 KV/mm |
| Surface resistivity | cond | IEC 60093 | 10 Ω |
| Volume resistivity | dry,cond | IEC 60093 | 10 Ω.cm |
| Physical properties | Test Condition | Test Method | EMS-CHEMIE SWITZERLAND/LV-3H |
|---|---|---|---|
| Shrinkage rate | trans,Across Flow,dry | ISO 294 | 0.75 % |
| long,Across Flow | ISO 294 | 0.10 % |