Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PBT SK601 NC010 DUPONT SHENZHEN
Zytel®
Electronic and electrical components,Automotive Applications,Industrial applications,Automotive Applications,Industrial applications,Automotive Applications
Glass fiber reinforced,Filler: Glass fiber reinf,Good strength (glass fibe,20% by weight ratio),20% filler by weight,Good strength (glass fibe,20% by weight ratio),20% filler by weight
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Other performance | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
Extreme Oxygen Index | ISO 4589-1 | 19 % |
Supplementary Information | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
EmissionofOrganicCompounds | VDA277 | 140 µgC/g | |
Odor | VDA270 | 3.00 |
thermal performance | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
Hot deformation temperature | 0.45 Mpa,Unannealed | ISO 75B-1 | 220 ℃ |
0.45MPa,Unannealed | ISO 75-2/B | 220 °C | |
1.8MPa,Unannealed | ISO 75-2/A | 204 °C | |
1.80 Mpa,Unannealed | ISO 75B-1 | 204 ℃ | |
Linear coefficient of thermal expansion | 平行Flow,23 to 55℃(73 to 130°F) | ISO 11359-1 | 0.000100 cm/cm/℃ |
垂直Flow,23 to 55℃(73 to 130°F) | ISO 11359-1 | 0.000040 cm/cm/℃ | |
TD | ISO 11359-2 | 1E-04 cm/cm/°C | |
MD | ISO 11359-2 | 4E-05 cm/cm/°C | |
Melting temperature | ISO 3146 | 225 ℃ | |
ISO 11357-3 | 224 °C | ||
UL flame retardant rating | 0.750 mm | UL 94 | HB |
1.50 mm | UL 94 | HB | |
3.00 mm | UL 94 | HB | |
Vicat softening temperature | ISO 306/B50 | 210 °C |
mechanical properties | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
Bending modulus | 23℃ | ISO 178 | 6200 MPa |
ISO 178 | 6500 Mpa | ||
bending strength | ISO 178 | 180 Mpa | |
23℃ | ISO 178 | 180 MPa | |
Charpy Notched Impact Strength | -30 ℃, Type 1, Edgewise, Notch A | ISO 179 | 9.8 KJ/m |
23℃, Type 1, Edgewise, Notch A | ISO 179 | 7.5 KJ/m | |
Impact strength of cantilever beam gap | 23 ℃, Type 1, Notch A | ISO 180 | 8 KJ/m |
Impact strength of simply supported beam without notch | -30℃, Type 1, Edgewise | ISO 179 | 54 KJ/m |
23 ℃, Type 1, Edgewise | ISO 179 | 56 KJ/m | |
Suspended wall beam without notch impact strength | 23 ℃, Type 1 | ISO 180 | 44 KJ/m |
Tensile creep modulus | 1000h | ISO 899-1 | 5600 MPa |
1hr | ISO 899-1 | 7200 Mpa | |
1000hr | ISO 899-1 | 5600 Mpa | |
1h | ISO 899-1 | 7200 MPa | |
Tensile modulus | ISO 527-2 | 7000 Mpa | |
23℃ | ISO 527-1 | 7400 MPa | |
Tensile strain | 23℃,Break | ISO 527-1 | 3.2 % |
Break | ISO 527-2 | 3.2 % | |
tensile strength | Break | ISO 527-2 | 120 Mpa |
Tensile stress | 23℃,Break | ISO 527-1 | 120 MPa |
Electrical performance | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 2 | |
Dielectric strength | IEC 60243-1 | 29 KV/mm | |
Dissipation factor | 1MHz | IEC 60250 | 0.019 |
100Hz | IEC 60250 | 1.2E-03 | |
Relative permittivity | 100Hz | IEC 60250 | 4.00 |
1MHz | IEC 60250 | 3.60 | |
Surface resistivity | IEC 60093 | 1E+15 ohms | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
density | ISO 1183 | 1.45 g/cm³ | |
ISO 1183 | 1.45 | ||
MediumDensity | 1.26 g/cm³ | ||
Shrinkage rate | Flow | ISO 294-4 | 0.35 % |
Across Flow | ISO 294-4 | 1.0 % | |
MD | ISO 294-4 | 0.30 % | |
TD | ISO 294-4 | 1.1 % | |
SpecificHeatCapacity of Melt | 1860 J/kg/°C | ||
ThermalConductivityofMelt | 0.25 W/m/K | ||
Top out temperature | 170 °C | ||
Water absorption rate | Sat/23C | ISO 62 | 0.4 % |
Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.15 % | |
23C/59RH | ISO 62 | 0.15 % | |
Saturation,23°C,2.00mm | ISO 62 | 0.40 % |
impact performance | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 8.0 kJ/m² |
-30°C | ISO 179/1eA | 9.0 kJ/m² | |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 8.0 kJ/m² |
23°C | ISO 180/1A | 9.0 kJ/m² | |
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 55 kJ/m² |
23°C | ISO 179/1eU | 60 kJ/m² | |
Suspended wall beam without notch impact strength | 23°C | ISO 180/1U | 60 kJ/m² |
-30°C | ISO 180/1U | 60 kJ/m² |
flammability | Test Condition | Test Method | DUPONT SHENZHEN/SK601 NC010 |
---|---|---|---|
Burning rate | 1.00mm | ISO 3795 | 28 mm/min |
Extreme Oxygen Index | ISO 4589-2 | 19 % | |
FMVSS flammability | FMVSS302 | B | |
Fogging-G-value | condensate)4 | ISO 6452 | 1E-04 g |
UL flame retardant rating | 0.75mm | UL 94 | HB |
0.75mm | IEC 60695-11-10,-20 | HB | |
1.5mm | IEC 60695-11-10,-20 | HB | |
1.5mm | UL 94 | HB |