plas
Log In

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA66 LUBEMID A26 TF10 NATURAL LUBEN PLAST srl
--
--
Filler, PTFE, Fiber, 10%, filler by weight,
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

thermal performanceTest ConditionTest MethodLUBEN PLAST srl/LUBEMID A26 TF10 NATURAL
Hot deformation temperature0.45MPa,UnannealedISO 75-2/B220to230 °C
1.8MPa,Unannealed,3.20mmASTM D64870.0to80.0 °C
0.45MPa,Unannealed,3.20mmASTM D648220to230 °C
Melting temperatureInternal Method250to265 °C
Vicat softening temperature--ISO 306/A120245to255 °C
--ISO 306/B120225to235 °C
mechanical propertiesTest ConditionTest MethodLUBEN PLAST srl/LUBEMID A26 TF10 NATURAL
Bending modulusISO 1782300to2700 MPa
bending strengthISO 17870.0to80.0 MPa
Tensile modulusISO 527-2/1A/12400to2800 MPa
Tensile strainBreakISO 527-2/1A/55.0to7.0 %
YieldISO 527-2/1A/55.0to7.0 %
tensile strengthBreakISO 527-2/1A/560.0to70.0 MPa
YieldISO 527-2/1A/560.0to70.0 MPa
Physical propertiesTest ConditionTest MethodLUBEN PLAST srl/LUBEMID A26 TF10 NATURAL
densityISO 1183/A1.20to1.21 g/cm³
impact performanceTest ConditionTest MethodLUBEN PLAST srl/LUBEMID A26 TF10 NATURAL
Charpy Notched Impact Strength23°CISO 179/1eA2.5to3.5 kJ/m²
Impact strength of cantilever beam gap23°C3ASTM D25645to55 kJ/m²
23°C4ASTM D2563.0to4.5 kJ/m²
23°CISO 180/A3.0to3.5 kJ/m²
23°C,3.20mmASTM D256A30to45 J/m
Impact strength of simply supported beam without notch23°CISO 179/1eU40to50 kJ/m²
Suspended wall beam without notch impact strength23°CISO 18045to55 kJ/m²