Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PPSU R-5800 CL 301 SOLVAY USA
RADEL® 
Medical devices、Electrical applications、household electrical appl
Resistance to stress crac、Thermal stability、High impact resistance
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

physical property
Test Condition
Test Method
Unit
PPSU/SOLVAY USA/R-5800 CL 301
density
ASTMD792
g/cm³
1
Melt mass flow rate
365°C/5.0kg
ASTMD1238
g/10min
2
Shrinkage rate
MD:3.18mm
ASTMD955
%
0
Water absorption rate
24hr
ASTMD570
%
0
Water absorption rate
平衡
ASTMD570
%
1
Mechanical performance
Test Condition
Test Method
Unit
PPSU/SOLVAY USA/R-5800 CL 301
Flexural Strength
5.0%Strain,3.18mm
ASTMD790
Mpa
9
TensileImpactStrength
3.18mm
ASTMD1822
kJ/m²
3
Tensile modulus
3.18mm
ASTMD638
Mpa
2
tensile strength
3.18mm
ASTMD638
Mpa
6
elongation
屈服,3.18mm
ASTMD638
%
7
elongation
断裂,3.18mm
ASTMD638
%
6
Bending modulus
3.17mm
ASTMD790
Mpa
2
Impact strength of cantilever beam gap
3.17mm
ASTMD256
J/m
6
Thermal performance
Test Condition
Test Method
Unit
PPSU/SOLVAY USA/R-5800 CL 301
Glass transition temperature
DSC
°C
2
Hot deformation temperature
1.8MPa,未退火,3.18mm
ASTMD648
°C
2
Linear coefficient of thermal expansion
MD:3.18mm
ASTMD696
cm/cm/°C
5
Electrical performance
Test Condition
Test Method
Unit
PPSU/SOLVAY USA/R-5800 CL 301
VolumeResistivity
3.18mm
ASTMD257
ohms·cm
9
Dielectric strength
0.0254mm
ASTMD149
KV/mm
>
Dielectric strength
3.18mm
ASTMD149
KV/mm
1