Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 NILAMID® A3 GF30 TM2 Celanese Corporation
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | Celanese Corporation/NILAMID® A3 GF30 TM2 |
|---|---|---|---|
| Ball Pressure Test | 125°C | IEC 60695-10-2 | 通过 |
| 165°C | IEC 60695-10-2 | 通过 | |
| Continuous use temperature | IEC 60216 | 110 °C | |
| Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 260 °C |
| 1.8MPa,Unannealed | ISO 75-2/A | 254 °C |
| mechanical properties | Test Condition | Test Method | Celanese Corporation/NILAMID® A3 GF30 TM2 |
|---|---|---|---|
| Tensile modulus | 23°C | ISO 527-2 | 8500 MPa |
| Tensile strain | Break,23°C | ISO 527-2 | 3.0 % |
| tensile strength | Yield,23°C | ISO 527-2 | 135 MPa |
| Electrical performance | Test Condition | Test Method | Celanese Corporation/NILAMID® A3 GF30 TM2 |
|---|---|---|---|
| Compared to the anti leakage trace index | 3.20mm,SolutionA | IEC 60112 | PLC 1 |
| Dielectric strength | 2.00mm | IEC 60243-1 | 21 kV/mm |
| Surface resistivity | IEC 60093 | 1E+13 ohms | |
| Volume resistivity | 23°C | IEC 60093 | 1E+15 ohms·cm |
| Physical properties | Test Condition | Test Method | Celanese Corporation/NILAMID® A3 GF30 TM2 |
|---|---|---|---|
| density | 23°C | ISO 1183 | 1.37 g/cm³ |
| Shrinkage rate | TD:23°C | ISO 294-4 | 0.80 % |
| MD:23°C | ISO 294-4 | 0.30 % | |
| Water absorption rate | Saturation,23°C | ISO 62 | 5.0 % |
| 23°C,24hr | ISO 62 | 0.60 % |
| impact performance | Test Condition | Test Method | Celanese Corporation/NILAMID® A3 GF30 TM2 |
|---|---|---|---|
| Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 6.5 kJ/m² |
| -30°C | ISO 179/1eA | 5.5 kJ/m² | |
| Impact strength of cantilever beam gap | -30°C | ISO 180/A | 6.0 kJ/m² |
| 23°C | ISO 180/A | 8.0 kJ/m² | |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 28 kJ/m² |
| 23°C | ISO 179/1eU | 35 kJ/m² |
| flammability | Test Condition | Test Method | Celanese Corporation/NILAMID® A3 GF30 TM2 |
|---|---|---|---|
| Burning wire flammability index | 0.8mm | IEC 60695-2-12 | 650 °C |
| 3.2mm | IEC 60695-2-12 | 650 °C | |
| Extreme Oxygen Index | ISO 4589-2 | 27 % | |
| UL flame retardant rating | 3.2mm | UL 94 | HB |
| 0.8mm | UL 94 | HB | |
| 1.6mm | UL 94 | HB |