plas

Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA612/F/PTFE IFL-4036 SABIC INNOVATIVE US
LNP™ LUBRICOMP™ 
Electronic and electrical accessories
wear resistant
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

thermal performanceTest ConditionTest MethodSABIC INNOVATIVE US/IFL-4036
Hot deformation temperature1.8MPa,Unannealed,3.20mmASTM D648201 °C
1.8MPa,Unannealed,64.0mmSpanISO 75-2/Af198 °C
Linear coefficient of thermal expansionMD:-40to40°CASTME8312.5E-05 cm/cm/°C
TD:-40to40°CISO 11359-27.7E-05 cm/cm/°C
TD:-40to40°CASTME8317.6E-05 cm/cm/°C
MD:-40to40°CISO 11359-22.6E-05 cm/cm/°C
mechanical propertiesTest ConditionTest MethodSABIC INNOVATIVE US/IFL-4036
Bending modulusASTM D7908620 Mpa
ISO 1787920 Mpa
bending strengthISO 178232 Mpa
ASTM D790241 Mpa
elongationBreakASTM D6383.2 %
Friction coefficientDynamicASTM D3702Modified0.55
StaticASTM D3702Modified0.51
Tensile modulusASTM D6389970 Mpa
ISO 527-2/110300 Mpa
Tensile strainBreakISO 527-23.0 %
tensile strengthBreakISO 527-2157 Mpa
BreakASTM D638154 Mpa
Wear factorWasherASTM D3702Modified9.00 10^-10in^5-min/ft-lb-hr
Physical propertiesTest ConditionTest MethodSABIC INNOVATIVE US/IFL-4036
Shrinkage rateTD:24hrASTM D9550.80 %
TD:24hrISO 294-40.84 %
MD:24hrASTM D9550.20 %
MD:24hrISO 294-40.24 %
Water absorption rateEquilibrium,23°C,50%RHISO 620.17 %
24hr,50%RHASTM D5700.10 %
impact performanceTest ConditionTest MethodSABIC INNOVATIVE US/IFL-4036
Dart impact23°C,EnergyatPeakLoadASTM D376317.7 J
Impact strength of cantilever beam gap23°CISO 180/1A12 kJ/m²
Multi axis Instrumented Impact EnergyISO 6603-24.27 J
Suspended wall beam without notch impact strength23°CISO 180/1U73 kJ/m²