Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

POM 100 NC010 DUPONT JAPAN
Delrin®
Thin walled products,Fitness equipment
High rigidity,High hardness,Thermal stability,high viscosity,heat-resisting
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Supplementary Information | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
Emission | VDA275 | <8.00 mg/kg | |
EmissionofOrganicCompounds | VDA277 | 4.00 µgC/g |
hardness | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
Rockwell hardness | M-Sale | ISO 2039-2 | 90 |
R-Sale | ISO 2039-2 | 121 |
thermal performance | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 160 °C |
1.8MPa,Unannealed | ISO 75-2/A | 100 °C | |
Linear coefficient of thermal expansion | TD:AnnealingTime-Optional | ISO 11359-2 | 30.0 min/mm |
TD:-40to23°C | ISO 11359-2 | 1E-04 cm/cm/°C | |
MD:-- | ISO 11359-2 | 1.1E-04 cm/cm/°C | |
TD:AnnealingTemperature | ISO 11359-2 | 160 °C | |
MD:-40to23°C | ISO 11359-2 | 1E-04 cm/cm/°C | |
TD:-- | ISO 11359-2 | 1.1E-04 cm/cm/°C | |
TD:EffectiveThermalDiffusivity | ISO 11359-2 | 1E-07 m²/s | |
Melting temperature | ISO 11357-3 | 178 °C | |
Vicat softening temperature | -- | ISO 306/B50 | 160 °C |
-- | ISO 306/A50 | 175 °C |
mechanical properties | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
Bending modulus | ISO 178 | 2900 Mpa | |
bending strength | 3.5%Strain | ISO 178 | 79.0 Mpa |
Compressive stress | ISO 604 | 110 Mpa | |
Nominal tensile fracture strain | ISO 527-2 | 45 % | |
Tensile creep modulus | 1hr | ISO 899-1 | 2900 Mpa |
1000hr | ISO 899-1 | 1600 Mpa | |
Tensile modulus | ISO 527-2 | 3000 Mpa | |
Tensile strain | Yield | ISO 527-2 | 26 % |
tensile strength | Yield | ISO 527-2 | 72.0 Mpa |
Electrical performance | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | V | |
Dielectric strength | IEC 60243-1 | 41 KV/mm | |
Dissipation factor | 1MHz | IEC 60250 | 5.5E-03 |
100Hz | IEC 60250 | 1E-03 | |
Relative permittivity | 100Hz | IEC 60250 | 3.90 |
1MHz | IEC 60250 | 3.80 | |
Surface resistivity | IEC 60093 | 3E+13 ohms | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
MediumDensity | 1.19 g/cm³ | ||
melt mass-flow rate | ISO 1133 | 2.3 g/10min | |
Melt Volume Flow Rate (MVR) | 190°C/2.16kg | ISO 1133 | 1.90 cm3/10min |
Shrinkage rate | MD | ISO 294-4 | 2.2 % |
TD | ISO 294-4 | 1.8 % | |
SpecificHeatCapacity of Melt | 3000 J/kg/°C | ||
Water absorption rate | Equilibrium,23°C,2.00mm,50%RH | ISO 62 | 0.20 % |
Saturation,23°C,2.00mm | ISO 62 | 0.90 % |
impact performance | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 430 kJ/m² |
23°C | ISO 179/1eU | NoBreak |
flammability | Test Condition | Test Method | DUPONT JAPAN/100 NC010 |
---|---|---|---|
Atomization | G-value(condensate) | ISO 6452 | 1E-04 g |
F-value(refraction) | ISO 6452 | 91 % | |
Burning rate | 1.00mm | ISO 3795 | 30 mm/min |
FMVSS flammability | FMVSS302 | B | |
UL flame retardant rating | 0.8mm | IEC 60695-11-10,-20 | HB |
1.5mm | IEC 60695-11-10,-20 | HB | |
0.8mm | UL 94 | HB | |
1.5mm | UL 94 | HB |