Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

ABS Ultra 4105 ELIX Polymers, S. L.
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | ELIX Polymers, S. L./Ultra 4105 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 40 kJ/m² |
-30°C | ISO 179/1eA | 30 kJ/m² | |
Impact strength of cantilever beam gap | -30°C | ISO 180/1A | 34 kJ/m² |
23°C | ISO 180/1A | 42 kJ/m² |
hardness | Test Condition | Test Method | ELIX Polymers, S. L./Ultra 4105 |
---|---|---|---|
ball-indentation hardness | ISO 2039-1 | 85.0 MPa |
Electrical performance | Test Condition | Test Method | ELIX Polymers, S. L./Ultra 4105 |
---|---|---|---|
Volume resistivity | IEC 60093 | 6E+16 ohms·cm | |
relative permittivity | 23°C,1MHz | IEC 60250 | 3.00 |
23°C,100Hz | IEC 60250 | 3.00 | |
Surface Resistivity | IEC 60093 | 2E+17 ohms | |
Dissipation Factor | 23°C,1MHz | IEC 60250 | 8.6E-03 |
23°C,100Hz | IEC 60250 | 3.8E-03 |
Mechanical properties | Test Condition | Test Method | ELIX Polymers, S. L./Ultra 4105 |
---|---|---|---|
tensile strength | 屈服,23°C | ISO 527-2/50 | 45.0 MPa |
Flexural modulus | 23°C | ISO 178 | 2000 MPa |
Tensile strain | 屈服,23°C | ISO 527-2/50 | 3.7 % |
tensile strength | 断裂,23°C | ISO 527-2/50 | 37.0 MPa |
Tensile strain | 断裂,23°C | ISO 527-2/50 | 30 % |
Nominal tensile fracture strain | 23°C | ISO 527-2/50 | 15 % |
Tensile modulus | 23°C | ISO 527-2/1 | 2000 MPa |
bending strength | 23°C | ISO 178 | 70.0 MPa |
flammability | Test Condition | Test Method | ELIX Polymers, S. L./Ultra 4105 |
---|---|---|---|
burning rate | 2.00mm | ISO 3795 | 34 mm/min |
Burning wire flammability index | 2.0mm | IEC 60695-2-12 | 700 °C |
UL flame retardant rating | 1.6mm | UL 94 | HB |
physical property | Test Condition | Test Method | ELIX Polymers, S. L./Ultra 4105 |
---|---|---|---|
density | 25°C | ISO 1183 | 1.07 g/cm³ |
Shrinkage rate | TD | ISO 2577 | 0.60to0.80 % |
MD | ISO 2577 | 0.60to0.80 % | |
Melt volume flow rate | 260°C/5.0kg | ISO 1133 | 14.0 cm³/10min |
Thermal performance | Test Condition | Test Method | ELIX Polymers, S. L./Ultra 4105 |
---|---|---|---|
Linear coefficient of thermal expansion | MD:23到55°C | ISO 11359-2 | 9E-05 cm/cm/°C |
vicat | ISO 306/B50 | 106 °C | |
Linear coefficient of thermal expansion | TD:23to55°C | ISO 11359-2 | 9E-05 cm/cm/°C |
Heat distortion temperature | 1.8MPa,退火,HDT | ISO 75-2/A | 99.0 °C |
0.45MPa,退火,HDT | ISO 75-2/B | 108 °C |
Contact Us