Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Polyester, TS Menzolit® SMC 2500 Menzolit Ltd (UK)
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| thermal performance | Test Condition | Test Method | Menzolit Ltd (UK)/Menzolit® SMC 2500 |
|---|---|---|---|
| Continuous use temperature | Internal Method | 165 °C | |
| Glass transition temperature | DSC | 170 °C | |
| Hot deformation temperature | 1.8MPa,Unannealed | ISO 75-2/A | >200 °C |
| Linear coefficient of thermal expansion | MD | ISO 11359-2 | 1.2E-05 cm/cm/°C |
| mechanical properties | Test Condition | Test Method | Menzolit Ltd (UK)/Menzolit® SMC 2500 |
|---|---|---|---|
| Bending modulus | Compression Molded | ISO 178 | 9000 MPa |
| bending strength | Compression Molded | ISO 178 | 145 MPa |
| Tensile modulus | Compression Molded | ISO 527-2 | 11000 MPa |
| tensile strength | Yield,Compression Molded | ISO 527-2 | 60.0 MPa |
| Electrical performance | Test Condition | Test Method | Menzolit Ltd (UK)/Menzolit® SMC 2500 |
|---|---|---|---|
| Compared to the anti leakage trace index | IEC 60112 | PLC 0 | |
| Dielectric strength | IEC 60243-1 | 36 kV/mm | |
| Dissipation factor | IEC 60250 | 0.010 | |
| Surface resistivity | IEC 60093 | 1E+13 ohms | |
| Volume resistivity | IEC 60093 | 1E+16 ohms·cm |
| Physical properties | Test Condition | Test Method | Menzolit Ltd (UK)/Menzolit® SMC 2500 |
|---|---|---|---|
| density | ISO 1183 | 1.80 g/cm³ | |
| Water absorption rate | Saturation,23°C | ISO 62 | <0.30 % |
| impact performance | Test Condition | Test Method | Menzolit Ltd (UK)/Menzolit® SMC 2500 |
|---|---|---|---|
| Charpy Notched Impact Strength | Compression Molded | ISO 179 | 65 kJ/m² |
| flammability | Test Condition | Test Method | Menzolit Ltd (UK)/Menzolit® SMC 2500 |
|---|---|---|---|
| Extreme Oxygen Index | ISO 4589-2 | 22 % | |
| UL flame retardant rating | 3.00mm | UL 94 | HB |