Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 FR7026V0FNC010 DUPONT SHENZHEN
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
Impact strength of simply supported beam without notch | 23°C | ISO 179/1eU | 80 kJ/m² |
hardness | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
ball-indentation hardness | H 358/30 | ISO 2039-1 | -- Mpa |
Mechanical properties | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
Tensile modulus | ISO 527-2 | 3800 Mpa | |
Nominal tensile fracture strain | ISO 527-2 | -- % | |
Tensile strain | 断裂 | ISO 527-2 | 10 % |
屈服 | ISO 527-2 | -- % | |
tensile strength | 断裂 | ISO 527-2 | 80.0 Mpa |
屈服 | ISO 527-2 | -- Mpa |
Electrical performance | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
Compared to the Leakage Tracking Index (CTI) | IEC 60112 | PLC 0 | |
dielectric strength | IEC 60243-1 | 31 KV/mm | |
Surface Resistivity | IEC 62631-3-2 | -- ohms | |
Compared to the Leakage Tracking Index (CTI) | UL 746 | PLC 0 |
flammability | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
Hot filament ignition temperature | 1.5 mm | IEC 60695-2-13 | 960 °C |
Burning wire flammability index | 0.75 mm | IEC 60695-2-12 | 960 °C |
Hot filament ignition temperature | 3.0 mm | IEC 60695-2-13 | 960 °C |
UL flame retardant rating | UL 94 | V-0 | |
Hot filament ignition temperature | 0.40 mm | IEC 60695-2-13 | 960 °C |
Burning wire flammability index | 3.0 mm | IEC 60695-2-12 | 960 °C |
Hot filament ignition temperature | 0.75 mm | IEC 60695-2-13 | 960 °C |
Limiting Oxygen Index | ISO 4589-2 | 39 % | |
Burning wire flammability index | 1.5 mm | IEC 60695-2-12 | 960 °C |
FMVSS combustion rate | FMVSS 302 | DNI | |
Burning wire flammability index | 0.40 mm | IEC 60695-2-12 | 960 °C |
Filling analysis | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
Ejection Temperature | 210 °C | ||
Odor | VDA 270 | 5.00 | |
Thermal Conductivity of Melt | 0.17 W/m/K | ||
Melt density | 1.03 g/cm³ | ||
Specific Heat Capacity of Melt | 2590 J/kg/°C |
physical property | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
Water absorption rate | 饱和, 23°C, 2.00 mm | ISO 62 | 8.0 % |
平衡, 23°C, 2.00 mm, 50% RH | ISO 62 | 2.4 % | |
viscosity number | ISO 307 | 160 cm³/g | |
Shrinkage rate | 流量 | ISO 294-4 | 0.90 % |
横向流量 | ISO 294-4 | 1.0 % |
Thermal performance | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
melting temperature | ISO 11357-3 | 260 °C | |
Heat distortion temperature | 0.45 MPa, 未退火,HDT | ISO 75-2/B | 230 °C |
1.8 MPa, 未退火,HDT | ISO 75-2/A | 80.0 °C | |
ball-indentation hardness | IEC 60309-1 | 220 °C |
injection | Test Condition | Test Method | DUPONT SHENZHEN/FR7026V0FNC010 |
---|---|---|---|
pressure holding | 50.0 to 100 Mpa | ||
Maximum Screw Tangential Speed | 12 m/min | ||
pressure holding | Drying Recommended | yes | |
Suggested maximum moisture content | 0.20 % | ||
Drying time - hot air dryer | 2.0 to 4.0 hr | ||
Processing (melt) temperature | 270 to 290 °C | ||
drying temperature | 80 °C | ||
Temperature | 50 to 90 °C | ||
Melt Temperature, Optimum | 280 °C | ||
Hold Pressure Time | 3.00 s/mm | ||
Mold Temperature, Optimum | 70 °C |