Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PPO HS2000X-80267 SABIC INNOVATIVE THAILAND
NORYL™
medical care
Glass fiber mineral reinf
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/HS2000X-80267 |
---|---|---|---|
23°C | ISO 180/1A | 9.7 kJ/m² | |
Dart impact | 23°C,TotalEnergy | ASTM D3763 | 443 J |
23°C | ASTM D256 | 130 J/m | |
Suspended wall beam without notch impact strength | 23°C | ASTM D4812 | 2200 J/m |
Reverse notch impact | 3.20mm | ASTM D256 | 810 J/m |
Electrical performance | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/HS2000X-80267 |
---|---|---|---|
Dissipation Factor | 50Hz | ASTM D150 | 0.017 |
60Hz | ASTM D150 | 0.017 | |
dielectric constant | 60Hz | ASTM D150 | 2.89 |
Volume resistivity | ASTM D257 | 1.2E+16 ohms·cm | |
dielectric constant | 50Hz | ASTM D150 | 2.89 |
Dissipation Factor | 1MHz | ASTM D150 | 4.4E-03 |
Surface Resistivity | ASTM D257 | >1.0E+16 ohms | |
High arc combustion index (HAI) | HAI | UL 746 | PLC 2 |
dielectric constant | 1MHz | ASTM D150 | 2.70 |
High Voltage Arc Traceability Rate (HVTR) | HVTR | UL 746 | PLC 3 |
dielectric strength | 3.20mm,inOil | ASTM D149 | 17 KV/mm |
Hot wire ignition (HWI) | HWI | UL 746 | PLC 0 |
arc resistance | ASTM D495 | PLC6 | |
Compared to the Leakage Tracking Index (CTI) | CTI | UL 746 | PLC 2 |
Mechanical properties | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/HS2000X-80267 |
---|---|---|---|
yield | ASTM D638 | 74.0 Mpa | |
ASTM D638 | 3.8 % | ||
fracture | ISO 527-2 | 11 % | |
100mm span 5 | 100mm | ASTM D790 | 3550 Mpa |
fracture | ASTM D638 | 60.0 Mpa | |
ISO 527-2 | 57.1 Mpa | ||
yield | ISO 527-2 | 71.7 Mpa | |
ISO 527-2 | 3.7 % | ||
fracture | ASTM D638 | 8.4 % | |
Yield, 100mm span | ASTM D790 | 117 Mpa | |
50.0mm span | ASTM D790 | 3670 Mpa | |
--1 | ASTM D638 | 3650 Mpa | |
Fracture, 50.0mm span | ASTM D790 | 117 Mpa |
flammability | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/HS2000X-80267 |
---|---|---|---|
UL flame retardant rating | 1.47mm | UL 94 | V-0 |
RadiantPanelListing(UL) | UL 94 | YES | |
2.01mm | UL 94 | 5VA |
physical property | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/HS2000X-80267 |
---|---|---|---|
Shrinkage rate | MD:3.20mm | 内部方法 | 0.50-0.70 % |
Melt volume flow rate | 300°C/5.0kg | ISO 1133 | 6.80 cm3/10min |
melt mass-flow rate | 300°C/5.0kg | ASTM D1238 | 7.6 g/10min |
Outdoor applicability | UL 746C | f1 | |
melt mass-flow rate | 280°C/5.0kg | ASTM D1238 | 7.6 g/10min |
Melt volume flow rate | 280°C/5.0kg | ISO 1133 | 6.80 cm3/10min |
Thermal performance | Test Condition | Test Method | SABIC INNOVATIVE THAILAND/HS2000X-80267 |
---|---|---|---|
0.45MPa, Unanealed, 6.40mm | ASTM D648 | 128 °C | |
0.45MPa, Unanealed, 100mm span | ISO 75-2/Be | 126 °C | |
Linear coefficient of thermal expansion | TD:-40到40°C | ASTME831 | 7.8E-05 cm/cm/°C |
1.8MPa, Unanealed, 100mm span | ISO 75-2/Ae | 111 °C | |
RTI Imp | UL 746 | 85.0 °C | |
1.8MPa, Unanealed, 3.20mm | ASTM D648 | 108 °C | |
1.8MPa, Unanealed, 6.40mm | ASTM D648 | 116 °C | |
RTI | UL 746 | 100 °C | |
Linear coefficient of thermal expansion | MD:-40到40°C | ASTME831 | 7.1E-05 cm/cm/°C |
RTI Elec | UL 746 | 100 °C | |
0.45MPa, Unanealed, 3.20mm | ASTM D648 | 117 °C |