PBT A GB 20 A SCHULMAN USA
SCHULADUR®
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
| hardness | Test Condition | Test Method | A SCHULMAN USA/A GB 20 |
|---|---|---|---|
| Ball Pressure Test | ISO 2039-1 | 113 Mpa |
| thermal performance | Test Condition | Test Method | A SCHULMAN USA/A GB 20 |
|---|---|---|---|
| Hot deformation temperature | 0.45MPaUnannealed | ISO 75-2/Bf | 175 °C |
| 1.80MPaAnnealed | ISO 75-2/Af | 94 °C | |
| Vicat softening temperature | ISO 306/B50 | 184 °C | |
| ISO 306/A50 | 218 °C |
| mechanical properties | Test Condition | Test Method | A SCHULMAN USA/A GB 20 |
|---|---|---|---|
| Bending modulus | 23°C | ISO 178 | 3300 Mpa |
| bending strength | 23°C | ISO 178 | 83 Mpa |
| Charpy Notched Impact Strength | -30°C | ISO 179/1eA | 3.5 kJ/m² |
| 23°C | ISO 179/1eA | 5.0 kJ/m² | |
| Elongation at Break | 23°C | ISO 527-2 | 6.00 % |
| Impact strength of simply supported beam without notch | -30°C | ISO 179/1eU | 30 kJ/m² |
| 23°C | ISO 179/1eU | 50 kJ/m² | |
| Tensile modulus | 23°C | ISO 527-2 | 3400 Mpa |
| tensile strength | 23°C | ISO 527-2 | 50 Mpa |
| Physical properties | Test Condition | Test Method | A SCHULMAN USA/A GB 20 |
|---|---|---|---|
| melt mass-flow rate | 250℃/2.16Kg | ISO 1133 | 15.0 cm3/10min |
| flammability | Test Condition | Test Method | A SCHULMAN USA/A GB 20 |
|---|---|---|---|
| Ignition temperature of heating wire | 1.50mm | IEC 60695-2-12 | 725 °C |
| 3.00mm | IEC 60695-2-12 | 725 °C | |
| Relative temperature of heating wire | 1.50mm | IEC 60695-2-13 | 750 °C |
| 3.00mm | IEC 60695-2-13 | 750 °C | |
| UL flame retardant rating | UL -94 | HB 1.60mm | |
| UL -94 | HB 3.20mm |