Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PC+ABS FR411 MT Covestro - Polycarbonates
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Covestro - Polycarbonates/FR411 MT |
---|---|---|---|
Suspended wall beam without notch impact strength | 23°C | ISO 180 | 43 kJ/m² |
Impact strength of cantilever beam gap | 23°C | ISO 180/A | 6.0 kJ/m² |
Electrical performance | Test Condition | Test Method | Covestro - Polycarbonates/FR411 MT |
---|---|---|---|
dielectric strength | 23°C,1.00mm | IEC 60243-1 | 39 kV/mm |
relative permittivity | 23°C,1MHz | IEC 60250 | 3.10 |
Volume resistivity | 23°C | IEC 60093 | 4E+17 ohms·cm |
relative permittivity | 23°C,100Hz | IEC 60250 | 3.20 |
Compared to the Leakage Tracking Index (CTI) | 解决方案A | IEC 60112 | PLC 3 |
Surface Resistivity | IEC 60093 | 5E+16 ohms | |
Dissipation Factor | 23°C,1MHz | IEC 60250 | 7.6E-03 |
23°C,100Hz | IEC 60250 | 6.1E-05 |
Mechanical properties | Test Condition | Test Method | Covestro - Polycarbonates/FR411 MT |
---|---|---|---|
tensile strength | 屈服,23°C | ISO 527-2/50 | 67.0 MPa |
Tensile strain | 屈服,23°C | ISO 527-2/50 | 3.0 % |
tensile strength | 断裂,23°C | ISO 527-2/50 | 59.0 MPa |
Tensile strain | 断裂,23°C | ISO 527-2/50 | 5.0 % |
Tensile modulus | 23°C | ISO 527-2/1 | 5250 MPa |
flammability | Test Condition | Test Method | Covestro - Polycarbonates/FR411 MT |
---|---|---|---|
UL flame retardant rating | 0.75mm | UL 94 | V-0 |
3.0mm | UL 94 | 5VB | |
1.5mm | UL 94 | V-0 |
physical property | Test Condition | Test Method | Covestro - Polycarbonates/FR411 MT |
---|---|---|---|
density | 23°C | ISO 1183 | 1.36 g/cm³ |
Shrinkage rate | TD:3.00mm | ISO 2577 | 0.20to0.40 % |
Water absorption rate | 平衡,23°C,50%RH | ISO 62 | 0.10 % |
饱和,23°C | ISO 62 | 0.40 % | |
MeltViscosity | ISO 11443-A | 240 Pa·s | |
Melt volume flow rate | 260°C/5.0kg | ISO 1133 | 15.0 cm³/10min |
Shrinkage rate | MD:3.00mm | ISO 2577 | 0.30to0.50 % |
Thermal performance | Test Condition | Test Method | Covestro - Polycarbonates/FR411 MT |
---|---|---|---|
vicat | -- | ISO 306/B120 | 99.0 °C |
Linear coefficient of thermal expansion | MD:23到55°C | ISO 11359-2 | 4E-05 cm/cm/°C |
Heat distortion temperature | 0.45MPa,未退火,HDT | ISO 75-2/B | 93.0 °C |
Linear coefficient of thermal expansion | TD:23to55°C | ISO 11359-2 | 6E-05 cm/cm/°C |
Heat distortion temperature | 1.8MPa,未退火,HDT | ISO 75-2/A | 87.0 °C |
vicat | -- | ISO 306/B50 | 97.0 °C |
Contact Us
Get App
Top