Material Comparison

Product Info
Product Name
Brand Name
Usages
Properties
Certificates
PA6 C 50H2 SOLVAY FRANCE
TECHNYL® 
Laptop case
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--

Plastic Datasheets

Supplementary InformationTest ConditionTest MethodSOLVAY FRANCE/C 50H2
EuropeanRailwaysCertificationsR22EN45545-2HL3
R25EN45545-2HL3
R23EN45545-2HL3
Mechanical propertiesTest ConditionTest MethodSOLVAY FRANCE/C 50H2
Tensile modulus23°CISO527-2/1A3500 Mpa
Electrical performanceTest ConditionTest MethodSOLVAY FRANCE/C 50H2
Surface ResistivityIEC600931E+15 ohms
IEC602503.50
CTI解决方案AIEC60112600 V
解决方案BIEC60112475 V
Volume resistivityIEC600931E+15 ohms·cm
Dissipation FactorIEC602500.020
dielectric strength2.00mmIEC60243-134 KV/mm
flammabilityTest ConditionTest MethodSOLVAY FRANCE/C 50H2
Hot filament ignition temperature3.2mmIEC60695-2-13700 °C
Burning wire flammability index0.8mmIEC60695-2-12960 °C
1.6mmIEC60695-2-12960 °C
FrenchSmokeIndexNFF16-101I2
Burning wire flammability index3.2mmIEC60695-2-12960 °C
Hot filament ignition temperature0.8mmIEC60695-2-13700 °C
1.6mmIEC60695-2-13700 °C
Limiting Oxygen IndexISO4589-236 %
FrenchFireIndexNFF16-101F2
UL flame retardant rating0.40mmUL94V-0
physical property Test ConditionTest MethodSOLVAY FRANCE/C 50H2
Water absorption rate23°C,24hrISO621.1 %

Contact Us

Get App

Top