Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

PA66 MT409AHS NC010 DUPONT USA
Zytel®
Electrical appliances
Thermal stability
UL
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Supplementary Information | Test Condition | Test Method | DUPONT USA/MT409AHS NC010 |
---|---|---|---|
EmissionofOrganicCompounds | VDA277 | 10.0 µgC/g | |
Odor | VDA270 | 4.00 |
thermal performance | Test Condition | Test Method | DUPONT USA/MT409AHS NC010 |
---|---|---|---|
Hot deformation temperature | 0.45MPa,Unannealed | ISO 75-2/B | 187 °C |
1.8MPa,Unannealed | ISO 75-2/A | 65.0 °C | |
Linear coefficient of thermal expansion | TD | ISO 11359-2 | 1E-04 cm/cm/°C |
MD | ISO 11359-2 | 1E-04 cm/cm/°C | |
Melting temperature | ISO 11357-3 | 262 °C |
mechanical properties | Test Condition | Test Method | DUPONT USA/MT409AHS NC010 |
---|---|---|---|
Bending modulus | ISO 178 | 2200 Mpa | |
Nominal tensile fracture strain | ISO 527-2 | 25 % | |
Tensile modulus | ISO 527-2 | 2400 Mpa | |
Tensile strain | Yield | ISO 527-2 | 5.0 % |
tensile strength | Yield | ISO 527-2 | 61.0 Mpa |
Electrical performance | Test Condition | Test Method | DUPONT USA/MT409AHS NC010 |
---|---|---|---|
Compared to the anti leakage trace index | IEC 60112 | PLC 0 | |
Dissipation factor | 1MHz | IEC 60250 | 0.013 |
100Hz | IEC 60250 | 6E-03 | |
Relative permittivity | 100Hz | IEC 60250 | 3.90 |
1MHz | IEC 60250 | 3.70 | |
Surface resistivity | IEC 60093 | -- ohms | |
Volume resistivity | IEC 60093 | >1.0E+15 ohms·cm |
Physical properties | Test Condition | Test Method | DUPONT USA/MT409AHS NC010 |
---|---|---|---|
density | ISO 1183 | 1.11 g/cm³ | |
Shrinkage rate | MD | ISO 294-4 | 1.7 % |
TD | ISO 294-4 | 1.7 % | |
Top out temperature | 190 °C | ||
Water absorption rate | 23°C,24hr | ISO 62 | 0.90 % |
impact performance | Test Condition | Test Method | DUPONT USA/MT409AHS NC010 |
---|---|---|---|
Charpy Notched Impact Strength | 23°C | ISO 179/1eA | 19 kJ/m² |
-40°C | ISO 179/1eA | 12 kJ/m² | |
Impact strength of cantilever beam gap | -40°C | ISO 180/1A | 11 kJ/m² |
-30°C | ISO 180/1A | 13 kJ/m² | |
23°C | ISO 180/1A | 17 kJ/m² |
flammability | Test Condition | Test Method | DUPONT USA/MT409AHS NC010 |
---|---|---|---|
Burning rate | 1.00mm | ISO 3795 | 29 mm/min |
FMVSS flammability | FMVSS302 | B | |
Fogging-G-value | condensate | ISO 6452 | 1E-04 g |
UL flame retardant rating | 0.8mm | IEC 60695-11-10,-20 | HB |
1.5mm | IEC 60695-11-10,-20 | HB | |
0.8mm | UL 94 | HB | |
1.5mm | UL 94 | HB |