Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Phenolic Resiten® G9 Iten Industries
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Iten Industries/Resiten® G9 |
---|---|---|---|
Impact strength of cantilever beam gap | 横向流量 | ASTM D256 | 640 J/m |
流量 | >770 J/m |
Electrical performance | Test Condition | Test Method | Iten Industries/Resiten® G9 |
---|---|---|---|
dielectric strength | --5 | ASTM D149 | 77000 V |
relative permittivity | 1MHz5 | ASTM D150 | 6.25 |
arc resistance | --7 | ASTM D495 | 197 sec |
dielectric strength | ASTM D149 | 14 kV/mm | |
arc resistance | --5 | ASTM D495 | 191 sec |
Dissipation Factor | 1MHz5 | ASTM D150 | 8.3E-03 |
1MHz6 | ASTM D150 | 8.4E-03 | |
relative permittivity | 1MHz6 | ASTM D150 | 6.34 |
dielectric strength | --7 | ASTM D149 | 62000 V |
Mechanical properties | Test Condition | Test Method | Iten Industries/Resiten® G9 |
---|---|---|---|
bending strength | --2 | 460 MPa | |
compressive strength | --2 | 214 MPa | |
--3 | 186 MPa | ||
bending strength | --3 | 358 MPa |
Contact Us
Get App
Top