Material Comparison
Product Info
Product Name
Brand Name
Usages
Properties
Certificates

Polyester BMC HT12-1026 Glastic Corporation
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
Plastic Datasheets
Impact resistance | Test Condition | Test Method | Glastic Corporation/BMC HT12-1026 |
---|---|---|---|
Suspended wall beam without notch impact strength | ASTM D256 | 330 J/m |
hardness | Test Condition | Test Method | Glastic Corporation/BMC HT12-1026 |
---|---|---|---|
Barcol Hardness | ASTM D2583 | 33 |
Mechanical properties | Test Condition | Test Method | Glastic Corporation/BMC HT12-1026 |
---|---|---|---|
bending strength | 屈服 | ASTM D790 | 148 MPa |
compressive strength | ASTM D695 | 163 MPa | |
Flexural modulus | ASTM D790 | 13100 MPa | |
tensile strength | 屈服 | ASTM D638 | 74.5 MPa |
Electrical performance | Test Condition | Test Method | Glastic Corporation/BMC HT12-1026 |
---|---|---|---|
dielectric strength | ASTM D149 | 15 kV/mm | |
arc resistance | ASTM D495 | 180 sec |
flammability | Test Condition | Test Method | Glastic Corporation/BMC HT12-1026 |
---|---|---|---|
UL flame retardant rating | 3.11mm | UL 94 | HB |
1.52mm | UL 94 | HB | |
2.22mm | UL 94 | HB |
physical property | Test Condition | Test Method | Glastic Corporation/BMC HT12-1026 |
---|---|---|---|
Shrinkage rate | MD | ASTM D955 | 0.15to0.25 % |
density | ASTM D792 | 1.85 g/cm³ |
Contact Us